摘要 电弧故障是引起电气火灾的原因之一,介绍了一种新型智能控制电弧故障断路装置。研究了电弧故障发生原理,开发了故障发生装置和完成了相应的电弧采集工作,并在此基础上提出了电弧故障复合判据。同时针对判断的需要设计了断路装置的硬件结构和软件流程,为低压配电保护系统增添了新的功能。研究结果表明,该装置的研制成功为低压保护电气开辟了新的领域。 Arc fault is always to be the reason why the electrical machine fires. A new type of intelligent control deviceIarc fault circuit interruputer was introduced. On the basis of studying the occurrence of arc fault and the corresponding collection of the arc, a composite criterion of arc fault was brought forward. Aiming at protecting the low-voltage distribution system,the hardware structure anti software processes of circuit device were designed, and new features to protect were added. The results indicate that the successful development of the dcviee has opened up a new area for low voltage electrical protection.
出处 《机电工程》 CAS 2009年第9期40-42,共3页 Journal of Mechanical & Electrical Engineering
关键词 电气火灾 电弧故障 断路装置 微控制单元 electrical fires arc fault circuit devices micro-control unit
  • 相关文献

参考文献12

二级参考文献30

  • 1梅雪,吴为麟.基于小波和ANN的电能质量分类方法[J].浙江大学学报(工学版),2004,38(10):1383-1386. 被引量:15
  • 2黄绍平,杨青,李靖.基于MATLAB的电弧模型仿真[J].电力系统及其自动化学报,2005,17(5):64-66. 被引量:87
  • 3[1]Chen S.Open design of networked power quality monitoring systems[J].IEEE Trans on Instrumentation and Measurement,2004,53(2):597-601. 被引量:1
  • 4[2]Makinen A,Parkki M,Jarventausta P,et al.Power quality monitoring as integrated with distribution automation[C]//16th International Conference and Exhibition on Electricity Distribution,Amsterdam,Netherlands:2001. 被引量:1
  • 5[3]Leou Rong-Ceng,Tsai Wen-Ruei,Chang Yong-Nong.A power quality monitoring system based on J2EE architecture[C]//TENCON 2004.2004 IEEE Region 10 Conference,Chiang Mai,Thailand:2004. 被引量:1
  • 6[4]Chua K Y,Tan K P,Ang T L.Integrated approach to on-line system wide power quality monitoring[C]//2004 International Conference on Power System Technology,Singapore:2004. 被引量:1
  • 7[5]Ducpyo Hong,Jinmok Lee,Jaeho Choi.Power quality monitoring system using power line communication[C] // 2005 Fifth International Conference on Information,Communications and Signal Processing,Bangkok,Thailand:2005. 被引量:1
  • 8Schavemaker P H.Arc model blockset[DB].Power Systems Laboratory,Delft University of Technolog-y,the Netherlands(eps.et.tudelft.nl),2001. 被引量:1
  • 9Habedank U.On the mathematical description of arc behaviour in the vicinity of current zero[J].etzArchiv,Vot,No.11,1988,10(11):339-343. 被引量:1
  • 10Van der Sluis L,Rutgers W R,Koreman C G A.A physical arc model for the simulation of current zero behwior of high-voltage circuit breakers[J].IEEE Trans on Power Delivery,1992,7(2):1016-1022. 被引量:1

共引文献124

同被引文献34

  • 1穆永保,张建成.IGBT型固态开关技术的研究[J].电气制造,2006(1):33-35. 被引量:5
  • 2李建基.开关设备中的故障电弧及其防护[J].江苏电器,2004(3):1-3. 被引量:2
  • 3杨福生.小波变换的工程分析与应用.清华大学电机与应用电子系讲义[M].,1997.. 被引量:2
  • 4印永嘉,陈洪亮.关于检测低压故障电弧的初步研究[J].实验室研究与探索,2007,26(8):20-23. 被引量:7
  • 5Underwriters Laboratories Inc.UL 1699,UL Standard for Safety for Arc-Fault Circuit-Interrupters[S]Chicago:Underwriters Laboratories. 被引量:1
  • 6Daubechies 1.Ten Lectures on Wavelet[M]Roma:Capital City Press. 被引量:1
  • 7RESTREPO C E. Arc fault detection and discrimination methods [C]//The 53rd IEEE Holm Conference on Electrical Contacts. Pittsburgh, PA, USA : IEEE, 2007 : 115 - 122. 被引量:1
  • 8BECK J,NEMIR D. Arc fault detection through model reference estimation[C]//Power Systems Conference. New Orleans,LA,USA: SAE, 2006 : 920-927. 被引量:1
  • 9KIM C J. Electromagnetic radiation behavior of low-voltage arcing fault[J]. IEEE Trans on Power Systems,2009,24(1):416-423. 被引量:1
  • 10MARTEL J M,ANHEUSER M,BERGER F. A study of arcing fault in the low-voltage electrical installation[C]//Proceedings of the 56th IEEE Holm Conference on Electrical Contacts (HOLM). Charleston,SC, USA :IEEE ,2010 : 199-219. 被引量:1

引证文献3

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部