期刊文献+

关于检测低压故障电弧的初步研究 被引量:7

Research on Detecting Low-Voltage Arc Fault
下载PDF
导出
摘要 低压故障电弧有引发火灾的危险,所以检测故障电弧是必要的。随着电力电子技术在低压领域的广泛应用,一些电器正常工作时的电压电流特性与故障电弧的典型特性相似,给检测工作带来了难度。研究调光灯及开关电源的工作原理可以发现,通过分析回路中电压电流在某些频率点的相位信息,可以有效判别是否发生了故障电弧。 Fire accident can arise from low-voltage arc fault, and so it is necessary to detect arc fault. As the electric power & electronic technology is used widely in low voltage area, the properties of voltage and current in normal working conditions of electrical appliance closely resemble or mimic the un-normal properties created by the arc fault, so it is difficult to distinguish between normal and un-normal cases. Through studying the principle of dimmer and switch power supply, it was found that in some frequency points, by analyzing the phase of electric voltage and current it can tell if arc faults occur.
出处 《实验室研究与探索》 CAS 2007年第8期20-23,共4页 Research and Exploration In Laboratory
关键词 电弧 电弧检测 相位 arc fault arc-fault detection phase
  • 相关文献

参考文献7

  • 1Gregory G D,Wong Kon,Dvorak R F.More about arc-fault circuit interrupters[ J ].IEEE Transactions on Industry Applications.2004,40(4):1006-1011. 被引量:1
  • 2王其平著..电器电弧理论[M].北京:机械工业出版社,1982:374.
  • 3拉弗蒂 J M.真空电弧理论和应用[M].北京:机械工业出版社,1985. 被引量:2
  • 4罗雷,刘晖.新型家用电弧故障断路器(AFCI)的开发[J].建筑电气,2006,25(2):11-16. 被引量:23
  • 5管致中,夏恭恪.信号与线性系统(上册)[M].北京:高等教育出版社,2002. 被引量:1
  • 6(日)原田耕介主编,耿文学译..开关电源手册 原书第2版[M].北京:机械工业出版社,2004:571.
  • 7童诗白.模拟电子技术基础[M].北京:高等教育出版社,2000.. 被引量:65

二级参考文献5

  • 1James E. Timperley.Incipient Fault Identification Through Neutral RF Monitoring of Large Rotating Machines. IEEE Transactions on Power Apparatus and Systems,1983, vol.PAS-102 (3) :693-698. 被引量:1
  • 2B. M. Aucoin, B. D. Russell. Distribution High Impedance Fault Detection Utilizing High Frequency Current Components.IEEE Transactions on Power Apparatus and Systems,1982,vol.PAS-101 (6) :1596-1606. 被引量:1
  • 3Mike Aucoin.Status of High Impedance Fault Detection.IEEE Transactions on Power Apparatus and Systems, 1985, vol.PAS-104 (3) :638-644. 被引量:1
  • 4Masayuki Okazaki, Tsuginori Inaba. Fault-Locating Method Using Harmonic Components of the Arc-voltage Waveform. Electrical Engineering in Japan, 1993, vol.113 (3) :27-35. 被引量:1
  • 5A. F. Sultan, G.W.Swift, D.J.Fedirehuk. Detecting Arcing Downed-wires Using Fault Current Flicker and Halfcycle Asymmetry. IEEE Transactions on Power Delivery, 1994,vol.9 (1) :461-469. 被引量:1

共引文献87

同被引文献81

引证文献7

二级引证文献70