摘要 目的分析多层螺旋CT图像伪影的影响因素,探讨处理方法,提高图像质量。方法回顾分析我院CT图像伪影的形成和特点,以及处理方法。结果多层螺旋CT图像伪影种类繁多,表现多样,但多能正确识别,选择正确的扫描方法和参数,可以减少伪影的产生。结论正确认识多层螺旋CT图像伪影产生的原理和处理措施,可以提高CT图像质量,有利于疾病的CT诊断,提高准确性。 Objective Analysis of multi-slice CT image artifact of the influencing factors, exploring ways to improve the image quality. Methods Retrospective analysis of CT images in our hospital the formation of artifacts and features, as well as treatment. Results The multi-slice CI" image a wide range of artifacts, the performance of diversity, but to correctly identify and select the correct scanning methods and parameters can be generated to reduce the artifacts. Conclusion The correct understanding of multi- slice CT image artifacts arising from the principle and deal with measures to improve the quality of CT images, CT is conducive to disease diagnosis, improve accuracy.
作者 毕勇
出处 《中外医疗》 2009年第27期165-165,共1页 China & Foreign Medical Treatment
关键词 体层摄影术 伪影 Tomography Artifact
  • 相关文献

参考文献1

二级参考文献8

  • 1Partial volume artifact reduction in computed tomography[C]. Jiang Hsieh, Applied Science Laboratory, G.E. Medical Systems, Proc. IEEE Intern. Conf. On image Processing,1996, 567-570. 被引量:1
  • 2Nonlinear Partial volume artifact correction in Helical CT[C]. Jiang Hsieh, Applied Science Laboratory, G.E. Medical Systems, Proc. IEEE Intern. Conf. On image Processing, 1999, 2035-2039. 被引量:1
  • 3Cause and correction for 3D Image Artifact in Helical CT[J]. Jiang Hsieh, Applied Science Laboratory, G.E. Medical Systems, Proc. IEEE Intern. Conf. On image Processing, 1999,2040-2044. 被引量:1
  • 4Reduction of mental streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm[C]. B.De Man etc., IEEE Intern. Conf. On image Processing, 2000,850-854. 被引量:1
  • 5Ge Wang etc.,Iterative Deblurring for CT Metal artifact reduction[J]. IEEE Transactions on medical imaging, 1996,Vol.15, NO.5, October, 657-664. 被引量:1
  • 6Chye Hwang Yan etc., Reconstruction Algorithm for polychromatic CT Imaging: Application to Beam Hardening Correction[J]. IEEE Transactions on medical imaging, 2000,Vol.19, NO.1. 被引量:1
  • 7Thomas H. Newton, M.D., D. Gordon Potts, M.D.Radiology of the skull and brain technical aspects of computed tomography[J ]. 1981, 3956-3992. 被引量:1
  • 8康晓东.现代医学影像技术[M].天津:天津科技翻译出版公司,1999.190-192. 被引量:3