期刊文献+

经食管实时三维超声心动图诊断房间隔缺损的应用价值 被引量:3

Primary study of the utility of transesophageal real-time three-dimensional echocardiography in the diagnosis of atrial septal defect
原文传递
导出
摘要 目的探讨经食管实时三维超声心动图(RT-3D-TEE)诊断房间隔缺损的应用价值。方法应用PhilipsiE33型彩色多普勒超声诊断仪,X7—2t经食管纯净波矩阵多平面实时三维探头,对经食管二维超声心动图(2D-TEE)检查的23例患者进行RT-3D-TEE检查。其中经胸二维(2D-TTE)诊断房间隔缺损20例,可疑房间隔缺损3例。结果23例患者均获得满意的三维图像,RT-3D-TEE可以从不同角度清楚显示房间隔缺损的位置、大小、有无残端及与毗邻结构的关系。23例患者RT-3D-TEE检查后全部明确诊断,其中房间隔缺损22例,卵圆孔未闭1例。在对房间隔缺损最大径的测量中,2DTTE、2D-TEE及RT-3D-TEE三种测量方法之间相比差异无统计学意义(P〉0.05)。RT-3D-TEE显示房间隔缺损直径测量值与手术实际测值呈高度相关。结论RT-3D-TEE具有实时、快速成像的特点,可以同步清晰显示房间隔缺损的位置、立体大小和毗邻结构的关系。 Objective To investigate the value of real-time three-dimensional transesophageal echocardiography(RT-3D-TEE) in the diagnosis of atrial septal defect. Methods Philips iE33 was used to detect twenty-three patients[17 female,6 male, mean age (34.4 ± 10.6) years], in which 20 patients were diagnosed in atrial septaldefect by transthoracic echocardiography(TTE), 3 patients with doubt of atrial septal defect. Results 3D images were clearly gained by RT-3D-TEE. It could detect the location,size,and extent of atrial septal defect. Twenty-three patients were definitely diagnosed,including atrial septal defect 22 cases,patent foramen ovale 1 case. There were no significant differences among the measurements for the size of atrial septal defect by 2D-TTE,2D-TEE and RT-3D-TEE ( P 〉0. 05). The diameter of atrial septal defect measured by RT-3D-TEE were highly correlated with surgical measurement. Conclusions RT-3D- TEE has the characteristic of on-line guidance and fastly obtaining 3D imaging. It can clearly show the location,size and the extent structures of atrial septal defect on line.
出处 《中华超声影像学杂志》 CSCD 北大核心 2009年第8期649-652,共4页 Chinese Journal of Ultrasonography
关键词 超声心动描记术 经食管 超声心动描记术 实时三维 房间隔缺损 Echocardiography, transesophageal Echocardiography, real-time three-dimensional Heart septal defects,atrial
  • 相关文献

参考文献13

二级参考文献20

  • 1刘岩,乔彬,朱萌,吴莉莉,张亮.实时三维超声心动图在引导房间隔缺损封堵术中的应用[J].中国医学影像技术,2004,20(z1):30-31. 被引量:5
  • 2王新房,李治安,谢明星,胡纲,刘俐,吕清,王连生.四维超声心动图的临床应用[J].中华心血管病杂志,1996,24(1):5-8. 被引量:17
  • 3Papavassion D,Doelling NR,Bowman K,et al. Initial experience with an internally ratating transthoracic three-dimensional echocar diographic probe and image acquisition on a conventional echocardiogram machine[J].Echocardiography,1998,15(4):369-376. 被引量:1
  • 4Cooke JC,Gelman JS,Harper RW.Echocardiologists role in the deployment of the amplatzer atrial septal occluder device in adults[J].J Am Soc Echocardiography,2001,14(6):588-594. 被引量:1
  • 5Magni G,Cao QL,Sugeng L,et al. Volume-rendered ,three-dimensional echocardiographic determination of the size,shape ,and position of atrial septal defects:validation in an in vitro model[J].Am heart J,1996,132(2pt1):376-381. 被引量:1
  • 6Cao Q,Radtke W,Berger F,et al. Transcatheter closure of multiple atrial septal defects.Initial results and value of two-and three-dimensional transoesophageal echocardiography[J].Eur Heart J,2000,21(11):941-947. 被引量:1
  • 7Acar P,Saliba Z,Bonhoeffer P,et al. Influence of atrial septal defect anatomy in patient selection and assessment of closure with the cardioseal device:a three-dimensional transoesophageal echocardiographic reconstruction[J].Eur Heart J,2000,21(7):573-581. 被引量:1
  • 8Sinha A,Nanda NC,Misra V,et al. Live three-dimensional transthoracic echocardiohraphic assessment of transcatheter closure of atrial septal defect and patent foramen ovale[J].Echocardiohraphy,2004,21(8):749-753. 被引量:1
  • 9Downing SW,herzog WR Jr,McElroy MC,et al.Feasibiligy of off-pump ASD colosure using real-time 3-D echocardiography[J].Heart Surg Forum,2002,5(2):96-99. 被引量:1
  • 10Wang XF,Deng YB,Nanda NC,et al.Live three-dimensional echocardiography:imaging principles and clinical application.Echocardiography,2003,20:593-604. 被引量:1

共引文献69

同被引文献21

  • 1马晓静,黄国英,贾兵.经食管超声心动图监测儿童经胸微创房间隔缺损封堵术[J].上海医学影像,2005,14(3):244-245. 被引量:2
  • 2邓东安,朱鲜阳,侯传举,韩秀敏.介入治疗继发孔房间隔缺损及合并畸形428例临床报告[J].中国介入影像与治疗学,2006,3(4):255-258. 被引量:5
  • 3Carpentier AF,Lessana A,Relland J,et al.The"physio-ring":an advanced concept in mitral valve annuloplasty.Ann Thorac Surg,1995,60:1177-1186. 被引量:1
  • 4Sharma R,Mann J,Drummond L,et al.The evaluation of realtime 3-dimensionsl transthoracic echocardiography for the preoperative functional assessment of patients with mitral valve prolapse:a comparison with 2-dimensional trasesophageal echocardiography.J Am Soc Echocardiography,2007,20:934-940. 被引量:1
  • 5Pothineni KR,Inamdar V,Miller AP,et al.Initial experience with live/real time three-dimensional transesophageal echocardiography.Echocardiography,2007,24;1099-1104. 被引量:1
  • 6Dickinson DF, Arnold R, Wilkinson JL, et al. Congenital heart disease among 160 4-80 liveborn children in livepool 1960-1969. Implication of surgical treatment. Br Heart J, 1981,46:55-62. 被引量:1
  • 7Huang CH, Lu CW, Lin TY, et al. Complication of intraop-erative transesophageal echocardiography in adult cardiac sur-gical patients-experience of two institutions in Taiwan. J Formos Med Assoc,2007, 106(1) :92-95. 被引量:1
  • 8卢漫,唐红,宋海波,史丽雅.二维及三维经食管超声心动图在心脏外科手术中的对比研究[J].中国超声医学杂志,2007,23(5):391-393. 被引量:9
  • 9Sugeng L, Shernan SK, Salgo IS, et al. Live 3-dimensional transesophageal echocardiography initial experience using the fully-sampled matrix array probe. J Am Coll Cardiol, 2008,52(6):446-449. 被引量:1
  • 10Kwak J, Andrawes M, Garvin S, et al. 3D transesophageal echocardiography: A review of recent literature 2007-2009. Curr Opin Anaesthesiol, 2010,23(1):80-88. 被引量:1

引证文献3

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部