期刊文献+

K_2CO_3溶液脱除CO_2最佳浓度的研究 被引量:4

An investigation on the optimum concentration of potassium carbonate aqueous solution for removal of carbon dioxide
下载PDF
导出
摘要 在实验室模拟脱碳装置上,对K2CO3溶液脱除CO2进行了实验研究。在恒定再生加热功率条件下以质量百分含量为18%~36%的K2CO3溶液考察了实验模拟装置的不同脱碳效果。结果表明w(K2CO3)为25%的溶液脱碳效果最佳。 An investigation on CO2 removal by potassium carbonate aqueous solution was carried out on a mimicked CO2 remoral experimental apparatus. Under certain heating power, the solution with a potassium carbonate mass fraction range from 18% to 36% was investigated, and the results indicated that the optimum potassium carbonate mass fraction of the solution is about 25%.
出处 《天然气化工—C1化学与化工》 CAS CSCD 北大核心 2009年第4期17-19,共3页 Natural Gas Chemical Industry
关键词 最佳浓度 碳酸钾溶液 二氧化碳脱除 optimum concentration potassium carbonate solution carbon dioxide removal
  • 相关文献

参考文献6

  • 1Benson H E,Field J H,Jimenson R M.CO2 absorption employing hot potassium carbonate solutions[J]. Chem Eng Prog,1954,50(7):356. 被引量:1
  • 2Benson H E,Field J H,Haynes W P.Improved process for CO2 absorportion uses hot carbonate solutions[J].Chem Eng Prog, 1956,52(10):433. 被引量:1
  • 3Benson H E,Field J H.New data for hot potassium carbonate progress[J].Petrol Refinery,1960,39,127-132. 被引量:1
  • 4Zhang X,Zhang C F,Xu G W,et al.An Experimental apparatus to mimic CO2 removal and optimum concentration of MEDA aqueous solution[J]. Ind Eng Chem Res,2001,40: 808-901. 被引量:1
  • 5张旭,张成芳,刘懿,吴勇强.实验室模拟脱碳装置及其脱碳溶液的综合评价[J].高校化学工程学报,2001,15(5):485-490. 被引量:5
  • 6张成芳 庄永定 刘凡 等.热碱和二乙醇胺催化热碱吸收二氧化碳的速率.化学工程,1981,(4):31-43. 被引量:1

二级参考文献4

共引文献4

同被引文献27

引证文献4

二级引证文献10