期刊文献+

湿法脱硫塔作除尘器使用的危害性 被引量:2

Hazardness research on using wet flue gas desulfurization absorber as dust collector
下载PDF
导出
摘要 介绍全国电厂脱硫设备近几年发展带来的若干问题。其中最主要的问题是设计时将脱硫塔作为除尘器使用,除尘效率为50%~80%不等,造成脱硫效率下降、除雾器、气-气热交换器(GGH)、循环浆液泵等旋转机械及石膏脱水等设备磨蚀、结垢或发生堵塞等事故,需要花费大量资金改造,造成经济损失。列举了脱硫塔作除尘器使用的危害性事例,希望引起有关方面重视。 Several problems brought by the development of flue gas desulfurization (FGD) equipments in recent years were introduced. Using FGD as dust collector was the cause of the dust removal efficiency reduction to 50%-80%, which will make several failures such as reduction of desulphurization efficiency, incrustation and jam of mist eliminator and gas-gas heat exchanger, and corrosion of rotating machinery (like circulating pump) and gypsum dehydration equipment. To solve these problems, transformations of the dust collector will bring about great economic losses. A variety of failures for using absorber as dust collector were listed in order to attract special attention.
出处 《中国电力》 CSCD 北大核心 2009年第8期70-74,共5页 Electric Power
关键词 脱硫塔 除尘器 故障 wet-FGD absorber dust collector failure
  • 相关文献

参考文献7

  • 1周生贤.在全国电力工业“上大压小、节能减排”工作会议上讲话[z].2007. 被引量:1
  • 2赵鹏高,严晨敏,潘超.二氧化硫排放总量控制若干问题思考[C]//2006年火电厂环境保护综合治理技术研讨会论文集.北京:中国电力杂志社,2006:27-30. 被引量:1
  • 3阎维平等编著..电站燃煤锅炉石灰石湿法烟气脱硫装置运行与控制[M].北京:中国电力出版社,2005:179.
  • 4冯全,郝建宏.定州电厂烟气系统的设计和运行分析[C]//火电厂烟气脱硫脱硝技术研讨会论文集,北京:中国电力杂志社、2005:191-192. 被引量:1
  • 5曾庭华,杨华等编著..湿法烟气脱硫系统的调试、试验及运行[M].北京:中国电力出版社,2008:887.
  • 6郝吉明等编著..燃煤二氧化硫污染控制技术手册[M].北京:化学工业出版社,2001:465.
  • 7江得厚,郝党强,王勤.燃煤电厂袋式除尘器发展趋势及其运行寿命的影响因素[J].中国电力,2008,41(5):86-91. 被引量:49

二级参考文献10

共引文献48

同被引文献11

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部