期刊文献+

基于电化学方法设计的唾液葡萄糖检测仪

Electrochemistry-based design of a detector for saliva glucose
下载PDF
导出
摘要 旨在设计一种基于电化学方法的唾液葡萄糖检测仪,根据糖尿病患者的唾液葡萄糖含量与血糖含量的相关性,通过检测糖尿病患者的唾液葡萄糖含量,实现糖尿病患者的无创病情监控。实验制备普鲁士蓝修饰电极作为三电极系统的工作电极,提高电极对H2O2的电催化还原反应的灵敏度,降低工作电压。利用三电极检测系统,检测在葡萄糖氧化酶催化作用下葡萄糖氧化还原反应产生的电流。采用屏蔽层驱动技术,避免检测到的微弱信号在传输过程中的衰减,从而达到准确测量。采用单片机C8051F020对整个系统进行控制,并且为电极提供扫描电压,对检测结果进行A/D转换等处理,最后将结果显示在液晶屏上。该检测仪工作电压为0.496V,检测灵敏度为0.1mmol/L;由该仪器检测的唾液葡萄糖浓度与精密分析仪蓝标LK98B型测得的结果只差一个比例常数。结果提示,该唾液葡萄糖检测仪具有工作电压低、灵敏度高、总体性能良好的特点,可以达到检测要求。 A kind of saliva glucose detector based on electrochemistry is designed to measure the saliva glucese of diabetes mellitus, so as to achieve non-invasive measurement for diabetes mellitus state. A Prussian blue modified glassy carbon electrode was designed as the working electrode of the three-electrode system to improve the electrode sensitivity to H2O2's electrochemical reaction in a lower voltage. A three-electrode system was employed for measuring the current generated by the oxidation-reduction reaction of glucose catalyzed by glucose oxidase. Technique of shield-driving was used to avoid the attenuation of the voltage when it was processed, so as to ensure the precision measurement. A single chip microcomputer, C8051F020, was used to control the system and provide scanning voltage for the electrode, make A/D transition and process the result. Then the outputs were displayed on liquid crystal display. This detector's operating voltage was 0.496 V. The sensltivity was 0.1 mmol/L. There was a constant of proportionality between the measuring results of this detector and the precise analysator, Lanbiao LK98B. Results of the study show that this detector has low operating voltage, high sensitivity and good function of whole system, and can meet the request of measure.
出处 《中国组织工程研究与临床康复》 CAS CSCD 北大核心 2009年第30期5915-5918,共4页 Journal of Clinical Rehabilitative Tissue Engineering Research
  • 相关文献

参考文献35

  • 1Legro RS,Kunselman AR,Dodson WC.et al.Prevalence and predictors of risk for type 2 diabetes mellitus and impaired glucose tolerance in polycystic ovary syndrome:A prospective.controlled study in 254 affected women.J Clin Endocrinol Metab.1999;84(1):165-169. 被引量:1
  • 2Yusuf S,Gerstein H,Hoogwerf B,et al.Ramipdl and the development of diabetes.JAMA.2001:286(15):1882-1885. 被引量:1
  • 3Chowdhury TA.Tvpe 2 diabetes in people of south Asian origin:potential strategies for prevention.British J Diabetes Vas Dis.2007;7(6):279-282. 被引量:1
  • 4Ma XG,Pu XY,Chen SG.Shengwu Yixue Gongchengxue Zazhi.2004;21(3):473-475. 被引量:1
  • 5马显光,蒲晓允,陈仕国,蒋洪,叶勇.无创血糖仪的研制[J].生物医学工程学杂志,2004,21(3):473-475. 被引量:6
  • 6Marks v.An improved glucose-oxidase method for determining blood.C.S.F.and urine glucose levels.Clinica Chimica Acta.2006;251(1):19-24. 被引量:1
  • 7Yamaguchi M,Mjtsumori M,Kano Y.Noninvasively measudng blood glucose using saliva.IEEE Eng Med Biol Mag.1998;17(3):59-63. 被引量:1
  • 8Ginsberg BH.An overview of minimally invasive technologies.Clin Chem.2006;38(9):1596-1600. 被引量:1
  • 9Belazi MA,Galli TA,Drakoulakos D,et al.Salivary altemtions in insulin-dependent diabetes mellitus.Int J Paediatr Dent.2007;8(11):29-33. 被引量:1
  • 10Zhang HY.Qilu Yixue Jianyan.2005;16(3):17-19. 被引量:1

二级参考文献27

  • 1李荐,钟晖,钟海云,戴艳阳,温俊杰.超级电容器应用设计[J].电源技术,2004,28(6):388-391. 被引量:35
  • 2倪惠兰,郑淑香,沈慧安,施莉莉.糖耐量减低及糖尿病患者的血液粘度变化[J].北京医学,1994,16(1):14-17. 被引量:5
  • 3曾卫民,王连春,陈正炎,杨仁传,唐梦萱,胡晓萍.葡萄糖苯脎分光光度法测定血清糖化蛋白的初步研究[J].湖南医科大学学报,1994,19(6):491-494. 被引量:3
  • 4朱业湘,黄海潮,何亮,博敏恭,任恕.化学修饰GOD传感器[J].传感器技术,1997,16(1):25-29. 被引量:2
  • 5梁廷贵.集成运算放大器[A]..电压比较器分册[C].北京:科学技术文献出版社,2002.. 被引量:1
  • 6[1]Eftekhari Ali. Katz Eugenii,Heleg-Shabtai Vered, Willner Bilha, Willner Itamar,Bückmann Andreas F.. Electrical contact of redox enzymes with electrodes:novel approaches for amperometric biosensors. Bioelectrochemistry and Bioenergetics,1997,42(1):95~104. 被引量:1
  • 7[2]Chang Young Chung,Winarta Handani. Method of using enzyme electrode. Biotechnology Advances, 1995, 13(4):739. 被引量:1
  • 8BATFAGLINI F, BARTLETF P N, WANG J H. Covalent attachment of osmiun complexes to glucose oxidase and the application of the resulting modified enzyme in an enzyme switch responsive to glucose[J]. Anal Chem, 2000, 72(3): 502- 509. 被引量:1
  • 9NIU J J, LEE J Y. Reagentless mediated biosensors based on polyelectrolyte and sol - gel derived silica matrix [ J ]. Sensors and Actuators B, 2002, 82(2 - 3): 250- 258. 被引量:1
  • 10COSNIER S, SZUNERITS S, MARKS R S. A rapid and easy procedure of biosensor fabrication by microencapsulation of enzyme in hydrophilic synthetic latex films application to the amperometric determination of glucose[J ]. Electrochemistry Communication, 2000, 2(12): 851- 855. 被引量:1

共引文献69

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...