期刊文献+

星载微波辐射计定标热源研究 被引量:2

Study of the Calibration Hot Target for Spaceborne Microwave Radiometer
原文传递
导出
摘要 介绍了应用频率在10-90GHz波段的星载微波辐射计定标热源的结构及其功能;论述了定标热源微波吸收材料选择、吸收体结构设计、热设计及温度测控等技术与方法;给出了定标热源吸收率和温度特性测试结果。地面和在轨运行均表明,该定标热源满足星载微波辐射计设计要求。 In this paper,structure and functions of a Calibration Hot Target for Spaceborne Microwave Radiometer (the frequency range from 10 GHz to 90 GHz) is presented. Material selecting, structure designing of absorber, thermal designing as well as temperature measuring and controlling are also described and absorb rate and performance testing results the temperature are presented. The data of ground and orbit operation shows that the Calibration Hot Target accorded with Microwave Radiometer design.
机构地区 兰州物理研究所
出处 《遥感技术与应用》 CSCD 北大核心 2009年第3期391-394,共4页 Remote Sensing Technology and Application
关键词 微波辐射计 定标热源 吸收体 发射率 Microwave Radiometer Calibration Hot Target Blackbody Emissivity
  • 相关文献

参考文献7

  • 1乌拉比,穆尔.微波遥感(第一卷)[M].北京:科学出版社,1987. 被引量:2
  • 2李靖,姜景山,李茂堂.微波辐射计定标[J].遥感技术与应用,1999,14(1):1-4. 被引量:11
  • 3翟宏.微波辐射计定标源关键技术探讨[C].第15届全国微波遥感技术学术交流会,2005,59-60. 被引量:2
  • 4肖志辉,郭伟,张祖荫.微波辐射计热定标源的研究与计算[J].华中科技大学学报(自然科学版),2001,29(10):4-6. 被引量:2
  • 5刘顺华,刘军民,董星龙,等.电磁渡屏蔽及吸波材料[M].北京:化学工业出版社,2007,305-308. 被引量:1
  • 6Battistelli E,Galileo O,Bordi R,et al.Ground Calibration Targets for MIMR Radiometer System Testing[J].IEEE,1998,3498:106-107. 被引量:1
  • 7Battistelli E,Abbate M L,Spera P.Blackbody Target Devices for MIMR Calibration[J].Geoscience and Remote Sensing Symposium,1995,1:10-14. 被引量:1