摘要
通过正交试验设计和自制隔热检测装置确定了最佳实验方案,自制水性薄型热反射隔热保温涂料的性能达到了建筑外表面用热反射隔热涂料标准(JC/T1040—2007)的要求,其中两项关键性能指标太阳反射比(白色)和半球发射率均高于标准要求。
With orthogonal design and self-made heat-insulating detecting device, the optimized experiment project was confirmed. The performance of self-made water-borne thin-layer reflective heat insulating coatings reached requirement of JC/T 1040-2007.Two key performance indexes, solar reflectance ratio (white) and hemisphere integrated radiant emittance, were both higher than that of standard requirement.
出处
《上海涂料》
CAS
2009年第6期14-16,共3页
Shanghai Coatings
关键词
水性涂料
隔热保温涂料
太阳反射比
半球发射率
water-borne coatings
heat insulating coatings
solar reflectance ratio
hemisphere integrated radiant emittance