期刊文献+

无汞排放的氧化铁含量测定方法

Determination Method of Iron Oxide Content with No Mercury Discharge
下载PDF
导出
摘要 常规测定氧化铁颜料中氧化铁含量时产生难以处置完全的含汞废水,污染环境。本文介绍了对有汞测定加以改进的无汞测定法,以甲基橙或三氯化钛代替氯化汞去除残留氯化亚锡。无汞法不仅效果令人满意,而且没有含汞废水,有利于环境保护。 The conventional determination method for iron oxide content in iron oxide pigments will produce a mercury - containing waste water which is difficult to be handled, causing environment pollution. This article has described a new mercury -free determination method for iron oxide, which used methyl orange or titanium trichloride instead of mercury chloride for removing of residual SnCl2. This method provided a satisfactory result, and no mercury -contianing waste water discharge.
作者 凌浩 麻毅
出处 《涂料工业》 CAS CSCD 北大核心 2009年第6期60-61,72,共3页 Paint & Coatings Industry
关键词 氧化铁 含汞废水 无汞测定 甲基橙 三氯化钛 环境保护 oxide iron waste water containing mercury mercury -free determination methyl orange titatium trichloride environmental protection
  • 相关文献

参考文献5

  • 1刘珍.化验员读本(第四版)[M].北京:化学工业出版社,2005:258-259. 被引量:2
  • 2邢文卫,陈艾霞编..分析化学[M].北京:化学工业出版社,2007:242.
  • 3甘峰编著..分析化学基础教程[M].北京:化学工业出版社,2007:154.
  • 4张小玲,张慧敏,邵清龙主编..化学分析实验[M].北京:北京理工大学出版社,2007:174.
  • 5沈苏江.部分无机颜料产品国内外标准及其技术差异[J].中国涂料,2006,21(7):16-19. 被引量:3