期刊文献+

不同对比剂剂量对肝脏螺旋CT增强扫描效果的影响 被引量:1

下载PDF
导出
出处 《郑州大学学报(医学版)》 CAS 北大核心 2009年第3期688-689,共2页 Journal of Zhengzhou University(Medical Sciences)
  • 相关文献

参考文献9

  • 1王超琴,高剑波,董军强,肖慧娟,谭延召,张伟,田辉英.影响肝脏螺旋CT增强强化效果相关因素分析[J].中国介入影像与治疗学,2008,5(4):291-293. 被引量:8
  • 2Ho LM, Nelson RC, Delong DM. Determining contrast medium dose and rate on basis of lean body weight: does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT [ J ]. Radiology, 2007,243 ( 2 ) :431 被引量:1
  • 3Yamashita Y,Komohara Y,Takahashi M,et al. Abdominal helical CT: evaluation of optimal doses of intravenous contrast material-a prospective randomized study[J]. Radiology,2000,216(3) :718 被引量:1
  • 4吴恩惠.医学影像学[M].北京:人民卫生出版社,2006:229 被引量:7
  • 5Ichikawa T, Erturk SM, Araki T. Muhiphasic contrast-en hanced multidetector-row CT of liver: contrast-enhancement theory and practical scan protocol with a combination of fixed injection duration and patients'body-weight-tailored dose of contrast material [ J ]. Eur J Radiol, 2006,58 ( 2 ) : 165 被引量:1
  • 6Awai K, Hiraishi K, Hori S. Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [ J ]. Radiology, 2004,230 (1):142 被引量:1
  • 7Weisbord SD, Palevsky PM. Radiocontrast-induced acute renal failure[ J ]. J Intensive Care M ed ,2005,20(2): 63 被引量:1
  • 8Al-Ghonaim M, Pannu N. Prevention and treatment of contrast-induced nephropathy[ J]. Tech Vasc lnterv Radiol,2006,9(2) : 42 被引量:1
  • 9Lameier NH. Contrast-induced nephropathy--prevention and risk reduction[J]. Nephrol Dial Transplant,2006,21 (6) :ill 被引量:1

二级参考文献10

  • 1[1]Rademacher G,Stengel D,Siegmann S,et al.Optimization of contrast agent volume for helical CT in the diagnostic assessment of patients with severe and multiple injuries.Comput Assist Tomogr,2002,26(1):113-118. 被引量:1
  • 2[2]Ho LM,Nelson RC,Delong DM.Determining contrast medium dose and rate on basis of lean body weight:does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT? Radiology,2007,243(2):431-437. 被引量:1
  • 3[3]Yanaga Y,Awai K,Nakayama Y,et al.Pancreas:patient body weight-tailored contrast material injection protocol versus fixed dose protocol at dynamic CT.Radiology,2007,245(2):475-482. 被引量:1
  • 4[4]Itoh S,Ikeda M,Satake H,et al.The effect of patient age on contrast enhancement during CT of the pancreatobiliary region.AJR Am J Roentgenol,2006,187(2):505-510. 被引量:1
  • 5[5]Yanaga Y,Awai K,Nakayama Y,et al.Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT.Radiat Med,2007,25(6):278-288. 被引量:1
  • 6[6]Ichikawa T,Erturk SM,Araki T.Multiphasic contrast-enhanced multidetector-row CT of liver:contrast-enhancement theory and practical scan protocol with a combination of fixed injection duration and patients' body-weight-tailored dose of contrast material.Eur J Radiol,2006,58(2):165-176. 被引量:1
  • 7[7]Awai K,Hori S.Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT.Eur Radiol,2003,13(9):2155-2160.. 被引量:1
  • 8[9]Suzuki H,Oshima H,Shiraki N,et al.Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta,portal vein and liver at multi-detector row CT:a randomized study.Eur Radiol,2004,14(11):2099-2104. 被引量:1
  • 9[10]Garcia P,Genin G,Bret PM.,et al.Hepatic CT enhancement:effect of the rate and volume of contrast medium injection in an animal model.Abdom Imaging,1999,24(6):597-603. 被引量:1
  • 10[11]Yamashita Y,Komohara Y,Takahashi M,et al.Abdominal helical CT:evaluation of optimal doses of intravenous contrast material-a prospective randomized study.Radiology,2000,216(3):718-723. 被引量:1

共引文献13

同被引文献7

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...