摘要
通过对锦州石化公司二套催化再生系统设备、烟气取样分析,以及对设备用材应力腐蚀敏感性评定,找出了设备失效原因,并提出了防护措施.
Through the analysis of sample equipment and flue gas of the regeneration system of No.2 FCCU in Jinzhou Petrochemical Company was well as the sensitivity study of stress corrosion of equipment materials, the causes of equipment failures were found out and protection measures were presented.
出处
《石油化工腐蚀与防护》
CAS
1998年第1期37-41,共5页
Corrosion & Protection In Petrochemical Industry
关键词
失效分析
催化再生系统
设备
炼油厂
腐蚀
regeneration system, failure analysis, flue gas composition