摘要 目的探讨l6层螺旋CT冠状动脉造影的最佳重建相位窗。方法32例健康受检者行16层CT冠状动脉成像检查,在6个相位窗(心动周期的R波后40%、50%、60%、70%、80%、90%)上对冠状动脉进行CT图像重组,对这6个时相的薄层图像进行最大密度投影、二维曲面重建、多平面重建和容积再现重建。结果每位受检者的4条冠状动脉分支(左冠状动脉主干、左前降支、左回旋支、右冠状动脉)分别用于图像质量分析。左主干在6个R-R时相均显示良好,左前降支、左回旋支在70%相位窗的图像质量最佳,右冠状动脉在80%相位窗的图像质量最佳,整体图像在70%相位窗的重组图像质量最佳。结论16层螺旋CT冠状动脉成像,应首先选择70%相位窗。选择最佳相位窗进行图像重建可以明显提高图像质量和工作效率。 Objective To evaluate the optimal reconstruction window during 16-slice spiral CT coronary angiography(MSCTA). Methods Thirty-two healthy subjects underwent MSCTA. Voluminal raw data were individually reconstructed at the starting points of 40%,50%,60%,70%,80% and 90% of intervals after the relative previous R waves.Thin images of six phases were acquired by MIP,CPR, MPR and VRT.Results Four coronary (LM,LAD,LCXmad RCA)segments were analyzed in image quality for each case.LM was well visual- ized in all 6 R-R phases.LAD and LCX were best visualized at 70% reconstruction window of the cardiac cycle,while RCA was best visu- alized at 80% reconstruction window of the cardiac cycle.MSCTA images acquired by volume rendering at 70% reconstruction window showed the optimal quality.Conclusion 70% reconstruction window of the cardiac cycle should be the first choice in MSCTA.Optimal reconstruction window can improve the quality of images and raise work efficiency obviously.
出处 《实用医学影像杂志》 2009年第2期83-85,共3页 Journal of Practical Medical Imaging
关键词 冠状血管造影术 体层摄影术 X线计算机 相位窗 Coronary angiography Tomography,X-ray computed Phasic window
  • 相关文献

参考文献7

  • 1Hong C, Becker CR, Huber A,et al. ECG-gated reconstructed multi- detector row CT coronary angiography: effect of varying trigger delay on image quality[J].Radiology, 2001,220(3 ) : 712-717. 被引量:1
  • 2Achenbach S, Giesler T, Ropers D, et al .Detection of coronary artery stenoses by contrast-enhanced,retrospectively electrocardiographically-gated,multi-slice spiral computed tomography[J]. Circulation, 2001, 103 ( 22 ) : 2535-2538. 被引量:1
  • 3Vogl TJ, Abohnaali N D, Diebold T, et al. Techniques for the detection of coronary atherosclerosis:multi-letector row CT coronary angiography[JJ. Radiology, 2002,223(1) : 212-220. 被引量:1
  • 4Achenbach S,Ulzheimer S, Baum U,et al.Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT [J]. Circulation,2000,102(23): 2823-2828. 被引量:1
  • 5Kopp AF, Schrneder S, Kuettner A, et al.Coronary arteries:retrospectively ECG-gated multi-delectorrow CT angiography with selective optimization of the image reconstruction window[J]. Radiology,2001, 221(3) :683-688. 被引量:1
  • 6蒋学祥,邱建星,王继琛,孙晓伟,高莉,高福生,王仪生.64层螺旋CT冠状动脉成像质量的研究[J].中国医学影像技术,2006,22(10):1452-1455. 被引量:31
  • 7王照谦,杨志强,朱皓,周旭臣,郑晓群,曲新凯,方唯一,刘晓峰.16层CT冠状动脉成像双扇区图像重建算法与相位窗的优选[J].放射学实践,2005,20(3):199-201. 被引量:14

二级参考文献16

  • 1王照谦,杨志强,朱皓,周旭臣,郑晓群,曲新凯,刘晓峰,方唯一.16层CT显示冠状动脉狭窄与导管法造影的对照研究[J].放射学实践,2005,20(3):190-194. 被引量:52
  • 2黄慧玲,潘爱珍,郑建忠,陈秀玲,欧阳瑞英.心率变化对16层螺旋CT冠状动脉成像质量的影响:减慢和稳定心率的方法与效果[J].中国CT和MRI杂志,2005,3(2):39-42. 被引量:24
  • 3李佩玲,徐克,黎庶,王强.心率对16层螺旋CT冠状动脉造影图像质量的影响及其重建相位窗的优选[J].中国介入影像与治疗学,2006,3(1):18-22. 被引量:22
  • 4Nieman K,Cademartiri F,Lemos PA,et al.Reliable Noninvasive Coronary Angiography with Fast Submillimeter Multislice Spiral Computed Tomography[J].Circulation,2002,106(16):2051-2054. 被引量:1
  • 5Schroeder S,Kopp AF,Kuettner A,et al.Influence of Heart Rate on Vessel Visibility in Noninvasive Coronary Angiography Using New Multislice Computed Tomography:Experience in 94 Patients[J].J of Clin Imag,2002,26(2):106-111. 被引量:1
  • 6Wang Zhaoqian,Zhu Hao,Shen Jingshun,et al.Retrospectively ECG-Gated Multislice CT Coronary Angiography:Optimization of the Image Reconstruction Window[J].Radiology,2002,225(9):703. 被引量:1
  • 7Leber A,Knez A,Ziegler F,et al.Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography:a comparative study with quantitative coronary angiography and intravascular ultrasound[J].J Am Coll Cardiol,2005,46(1):147-154. 被引量:1
  • 8Achenbach S,Giesler T,Ropers D,et al.Detection of coronary artery stenoses by contrast-enhanced,retrospectively electrocardiographically-gated,multislice spiral computed tomography[J].Circulation,2001,103(21):2535-2538. 被引量:1
  • 9Nieman K,Oudkerk M,Rensing BJ,et al.Coronary angiography with multi-slice computed tomography[J].Lancet,2001,357(9256):599-603. 被引量:1
  • 10Nieman K,Rensing B,van Geuns R,et al.Non-invasive coronary angiography with multislice spiral computed tomography:impact of heart rate[J].Heart,2002,88(5):470-474. 被引量:1

共引文献43

同被引文献6

  • 1Swets JA.Measuring the accuracy of diagnostic systems[J].Science,1988,240(4857):1285 -1293. 被引量:1
  • 2Soon KH,Chaitowitz I,Cox N,et al.Diagnostic accuracy of 16-slice CT coronary angio-graphy in the evaluation of coronary artery disease[J].Australas Radiol.2007,51(4):365-369. 被引量:1
  • 3Drosch T,Brodoefel H,Reimann A,et al.Prevalence and Clinical Characteristics of Symptomatic Patients with Obstructive Coronary Artery Disease in the Absence of Coronary Calcifications[J].Acad Radiol,2010,29(7):121-123. 被引量:1
  • 4de Queiroz Mello AP,da Silva IT,Oliveira AS,et al.Electronegative Low-Density Lipoprotein is Associated with Dense Low-Density Lipoprotein in Subjects with Different Levels of Cardiovascular Risk[J].Lipids,2010,24(10):68-71. 被引量:1
  • 5吴兆苏,姚崇华,赵冬,吴桂贤,王薇,刘静,曾哲淳,王文化.11省市队列人群心血管病发病前瞻性研究[J].中华心血管病杂志,1999,27(1):5-8. 被引量:138
  • 6韩玮,盖鲁粤,赵绍宏,聂永康,肖越勇.多层面螺旋CT冠状动脉成像在冠心病中的应用[J].中华老年心脑血管病杂志,2002,4(6):371-373. 被引量:13