摘要
以某住宅小区4栋多层住宅为例,通过对现浇钢筋混凝土楼板阳角切角斜裂缝的分析,阐明了其产生的原因,提出了建设性的防控意见。
Base on four multi-storey living buildings and through examination of break-corner inclined cracks of cast-in-place reinforced concrete slabs,producding reasons were indicated,some constructive suggestions about crack’s prevention and control were provided.