期刊文献+

脑电图双频谱指数预测七氟醚麻醉病人切皮体动反应的临床评价 被引量:6

The clinical evaluation of the bispectralindex of electroencephalogram in predicting movement during skin incision in patients under sevoflurane anesthesia
原文传递
导出
摘要 目的:用预测概率(P_K)评价七氟醚吸入麻醉时脑电图双频谱指数(BI)预测病人对切皮刺激体动反应的准确性。方法:选择行上腹部择期手术的成年患者29例,麻醉诱导用异丙酚及七氟醚,浓度随机为0.6MAC、1.0MAC、1.5MAC或2.0MAC的七氟醚维持15分钟以上切皮,观察病人的体动反应。取HR、MAP、SABP、BI及95%SEF等指标的切皮前1分钟数据,用于计算P_K。结果:MAC与BI预测概率显著高于0.5;95%SEF、SABP及MAP的预测概率稍低,但与0.5比较统计学上差别显著,其中95%SEF的P_K值与BI及MAC的P_K值比较差别显著;心率的P_K值接近0.5。结论:BI、SABP、MAP及95%SEF对七氟醚麻醉病人的切皮体动反应均有较好预测作用,但BI更敏感。 Objective: To evaluate the efficacy of the bispectral index (BI) in predicting patient movement on skin incision under sevoflurane anesthesia with the PK statistic. Method: Twenty-nine adult patients. scheduled for elective upper abdominal surgery, were selected. Anesthesia was induced with propofol and 4%-5% sevoflurane in oxygen and maintained with one of four randomized sevoflurane concentrations (0.6MAC, 1.0MAC. 1.5MAC and 2.0MAC) for fifteen minutes, then skin incision was performed by the surgeon at the planned site of the surgery, and each patient was observed carefully about 2 minutes to detect purposeful movement. The data of BI, 95% SEF, MAP, SABP and HR in one minute before skin incision were applied to statistically analysis. Result: The P_K was significantly greater than 0.5 for the sevoflurane level and the BI. The PK of 95% SEF. SABP and MAP were less than that of the level of sevoflu or Bl. but was significantly greater than 0.5 The P_K of HR was close to 0.5. Conclusion: These indicators of B, BP and 95% SEF may predict patient movement to skin incision under sevoflurane anesthesia. of which the BI is the most sensi tive.
出处 《中华麻醉学杂志》 CAS CSCD 北大核心 1998年第5期279-282,共4页 Chinese Journal of Anesthesiology
关键词 预测概率 七氟醚 脑电图 双频指数 麻醉深度 Prediction probability Electroencephalogram Sevoflurane Bispectral index Depth of anesthesia
  • 相关文献

参考文献1

  • 1韩文斌,国外医学.麻醉学与复苏分册,1997年,17卷,303页 被引量:1

同被引文献29

  • 1胡晓,孟美金,张京范.相同MAC浓度的安氟醚和异氟醚对脑电图功率谱的影响[J].中华麻醉学杂志,1995,15(10):443-445. 被引量:2
  • 2[25]Alkire MT,Gajraj RJ,Doi M.Analysis of the EEG bispectrum,auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness[J].Anesthesiology,1996,9:A174. 被引量:1
  • 3[1]Levy WJ,Cork P,Meathe E,et al.The use of quantitive elertroencepholography in different anesthtic methods[J].Anesthesiology,1980,53:223. 被引量:1
  • 4[2]Hudson RJ,Stanki DR,Saidman LJ,et al.A model for studying depth of anesthesia and acute tolerance to thiopental[J].Anesthesiology,1983,59:301. 被引量:1
  • 5[4]White PF.Clinical uses of intravenous anesthetic and analgesic infusions[J].Anesth Analg,1989,68:161-171. 被引量:1
  • 6[5]J Verson BM,S Boules MD,PS Sebel MB,et al.EEG Bispectrum predicts movement at incision during isoflurane or propofol anesthesia[J].Anesthesiology,1992,77:A502. 被引量:1
  • 7[6]Verson JM,Lang E,Sebel PS,et al.Prediction of movement using bispertral EEG during propofol/alfentanil or isoflurane/alfentanil anesthesia[J].Anesth Analg,1995,80:780. 被引量:1
  • 8[7]Alkire MD,Liu J,Singh D,et al.Elertroencephalographic bispectral indes correlates with intraoperative recall and depth of propofol-induced sedation[J].Anesth Analg,1996,82:S7. 被引量:1
  • 9[8]Kearse LA,Manbery P,Chamorch N,et al.Bispectral analysis of the eletroencephalogram correlates with patient movement to skin incision during propofol/nitrous oxide anesthesia[J].Anesthesiology,1994,81:1365. 被引量:1
  • 10[9]Kearse L,Roson C,Sebel P,et al.The bispectral index correlates with sedation/hypnosis and recall:comparison using multiple agents[J].Anesthesiology,1995,83(3A):A507. 被引量:1

引证文献6

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部