期刊文献+

等离子浸没注入对纯钛及钛合金表面耐腐蚀性能影响的研究 被引量:11

The Anticorrosion Research of Surface Modification of Pure Titanium and Ti6Al4V by Means of Plasma Ion Implantation Technique
下载PDF
导出
摘要 目的:通过等离子浸没注入对纯钛及钛合金试样进行表面改性,从而提高试样的耐腐蚀性能。方法:利用等离子浸没注入对纯钛及钛合金表面进行氮离子注入,通过电化学腐蚀实验和测定改性后试样在人工唾液中Ti离子的释放速率来评价其耐腐蚀性能。结果:电化学腐蚀法测得改性后纯钛及钛合金试样在人工唾液中的自腐蚀电位(Ecorr)分别比改性前增加了0·44V和0·4V,维钝电流(Ip)明显减小,改性试样在人工唾液浸泡90天后测得其Ti离子释放速率比改性前减少。结论:用氮等离子浸没注入的方法处理纯钛和钛合金试样,可以提高纯钛及钛合金试样的耐腐蚀性能。 Objective:To improve the anticorrosion of the modified surfaces of pure titanium and Ti6Al4V by means of plasma ion implantation technique.Methods:Nitrogen was implanted into the surface of pure titanium and Ti6Al4V using plasma ion implantation.The anticorrosive property was assessed by electro-chemical method and samples' release rate of Ti ion in the artificial saliva.Results:The electric potential of corrosion(Ecorr)of pure Titanium and Ti6Al4V was measured by electric-chemical method increased by 0.44V and 0.4V after modification.The two samples' Ip declined significantly.After immersion in artificial saliva for 90 days,the modified samples showed lower release rate of Ti ion.Conclusion:Plasma ion implantation improved the anticorrosive property of pure Titanium and Ti6Al4V.
出处 《华西医学》 CAS 2008年第3期473-474,共2页 West China Medical Journal
关键词 离子浸没注入 表面改性 纯钛 TI6AL4V 耐腐蚀性 plasma ion implantation,surface modification,pure titanium,Ti6Al4V,Anticorrosion
  • 相关文献

参考文献10

  • 1Kawahara H. Cytotoxicity of implantable metals and alloy [ J]. Bull Jpn Inst Met, 1992, 31 (12): 1033. 被引量:1
  • 2Yoshimitsu Okazaki, Yoshimasa Ito Y, Kenj Kyo, et al. Corrosion resisitance and corrosion fatigue strength of new titanimn alloys for medical implants without V and A1 [J]. Materials Science and Engineering, 1996, A213: 138. 被引量:1
  • 3Wang K. Thne use of titanium for medical applications in the USA [ J ]. Materials Science and Engineering, 1996, A213: 134. 被引量:1
  • 4Niinomi M, Kuroda D, Fuktmaga K, et al. Corrosion wear fracture of new βtype biomedical titanium alloys [ J ]. Materials Science and Engineering, 1996, A263: 193. 被引量:1
  • 5巍莹明.金属腐蚀理论及应用[M].第一版.化学工业出版社,1984. 被引量:1
  • 6Gerstorfer JG. In vitro corroion measurements of dental alloys [J]. J Dent, 1994, 22: 247- 251. 被引量:1
  • 7Cai Z, Vennilyea SG, Branfley. In vitro corrosion resistance of high - palladium dental casting alloys [ J ]. Dent Mater, 1999, 15: 202- 210. 被引量:1
  • 8Reclaru L, Meyer JM. Study of corrosion between a titanium implant and dental alloys [J]. J Dent, 1994, 22: 159-168. 被引量:1
  • 9Lucos, LC, Lemons JE, Biodegradation of restorative metallic systems [J]. Adv Dent Res, 1992, 6: 32. 被引量:1
  • 10Kononer MO. Lavonius ET, Kivilahti JK, SEM observation on stress corrosion cracking of commercially pure titanium in a topical fluoride solution [ J ]. Dental Materials, 1995, 11: 269. 被引量:1

同被引文献104