期刊文献+

Land subsidence induced by groundwater extraction and building damage level assessment—a case study of Datun, China 被引量:4

Land subsidence induced by groundwater extraction and building damage level assessment—a case study of Datun, China
下载PDF
导出
摘要 As in many parts of the world, long-term excessive extraction of groundwater has caused significant land-surface sub- sidence in the residential areas of Datun coal mining district in East China. The recorded maximum level of subsidence in the area since 1976 to 2006 is 863 mm, and the area with an accumulative subsidence more than 200 mm has reached 33.1 km2 by the end of 2006. Over ten cases of building crack due to ground subsidence have already been observed. Spatial variation in ground subsi- dence often leads to a corresponding pattern of ground deformation. Buildings and underground infrastructures have been under a higher risk of damage in locations with greater differential ground deformation. Governmental guideline in China classifies build- ing damages into four different levels, based on the observable measures such as the width of wall crack, the degree of door and window deformation, the degree of wall inclination and the degree of structural destruction. Building damage level (BDL) is esti- mated by means of ground deformation analysis in terms of variations in slope gradient and curvature. Ground deformation analysis in terms of variations in slope gradient has shown that the areas of BDL III and BDL II sites account for about 0.013 km2 and 0.284 km2 respectively in 2006, and the predicted areas of BDL (define this first) III and II sites will be about 0.029 km2 and 0.423 km2 respectively by 2010. The situation is getting worse as subsidence continues. That calls for effective strategies for subsidence miti- gation and damage reduction, in terms of sustainable groundwater extraction, enhanced monitoring and the establishment of early warning systems. As in many parts of the world, long-term excessive extraction of groundwater has caused significant land-surface subsidence in the residential areas of Datun coal mining district in East China. The recorded maximum level of subsidence in the area since 1976 to 2006 is 863 mm, and the area with an accumulative subsidence more than 200 mm has reached 33.1 km^2 by the end of 2006. Over ten cases of building crack due to ground subsidence have already been observed. Spatial variation in ground subsidence often leads to a corresponding pattern of ground deformation. Buildings and underground infrastructures have been under a higher risk of damage in locations with greater differential ground deformation. Governmental guideline in China classifies building damages into four different levels, based on the observable measures such as the width of wall crack, the degree of door and window deformation, the degree of wall inclination and the degree of structural destruction. Building damage level (BDL) is estimated by means of ground deformation analysis in terms of variations in slope gradient and curvature. Ground deformation analysis in terms of variations in slope gradient has shown that the areas of BDL III and BDL II sites account for about 0.013 km2 and 0.284 km2 respectively in 2006, and the predicted areas of BDL (define this first) III and II sites will be about 0.029 km2 and 0.423 km2 respectively by 2010. The situation is getting worse as subsidence continues. That calls for effective strategies for subsidence mitigation and damage reduction, in terms of sustainable groundwater extraction, enhanced monitoring and the establishment of early warning systems.
出处 《Journal of China University of Mining and Technology》 EI 2008年第4期556-560,共5页 中国矿业大学学报(英文版)
关键词 land subsidence groundwater extraction ground deformation slope gradient building damage level Datun China 地面沉降 地下水抽取 坡度 矿山安全
  • 相关文献

参考文献5

二级参考文献37

共引文献202

同被引文献18

引证文献4

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部