期刊文献+

MRI对急性主动脉夹层的诊断价值(附31例分析) 被引量:3

Diagnostic valuse of acute aorta dissection with MRI(a report of 31 cases)
下载PDF
导出
摘要 目的探讨急性主动脉夹层的MRI表现及诊断价值。方法采用超导型MR扫描机对31例主动脉夹层作不同序列技术的MR成像检查,介绍一种快速平衡稳态进动序列成像检查。结果主动脉夹层诊断准确率100%,磁共振表现为(1)不同信号双腔影;(2)剥离的内膜瓣;(3)破裂口;(4)血栓性主动脉夹层。结论磁共振成像对主动脉夹层的确诊具有重要价值。早期诊断、治疗是降低死亡率的关键。 Objective To investigate MRI findings and diagnostic value of aortic dissection. Methods 31 patients with acute aortic dissection were examined using Magnetic Resonance Imaging by applicaion of different pluse sequence techniques at Technicare 0.6 TandGE 1.5T Signa Excite Twinspeed. A Fast Imaging Employing Steady State Acquisition,(FIESTA)pulse sequence was introduced at 1.5T Signa Excite Twinspeed. Results The accuracy of MRI diagnosis rate was 100%. The MRI could demonstrate features included:(1)Double lumen with different attenuation values; (2) intimal flapserating the two chambers; (3)rupture of the bloodvessel; (4)thrombosed dissecting. Conclusion MRI is valuable for the diagnosis of acute aortic dissecting. Early diagnosis and treatment may be key to reduce the mortality rate.
出处 《中国CT和MRI杂志》 2008年第5期17-19,共3页 Chinese Journal of CT and MRI
关键词 急性 主动脉夹层 磁共振成像 acute aortic dissecting MRI
  • 相关文献

参考文献4

  • 1[1]De Bakey ME,Hemly da surgical of diassecting aneurysm of the heart.J Thoracic cardiovass,Surg,1965,45,130-149. 被引量:1
  • 2[3]Krinsky GA,Rofsky NM,Oecorato DR,et al.Thoracic aorta:Comparison of gadolinium enhanced three dimensional MR angiography withconventional MR imaging.Radiology,1997,202:183. 被引量:1
  • 3[4]Harthell GG.Imaging of aortic aneurysms and dissection:CT and MRI,J Thorae Imaging,2001,16:35 被引量:1
  • 4陈祖望,周康荣,陈福真,王述静,杨培强,沈继章,陈财忠,施伟斌.主动脉夹层几种磁共振影像的评价和比较[J].中华放射学杂志,1997,31(1):15-19. 被引量:24

二级参考文献1

共引文献23

同被引文献23

  • 1张波,府伟灵.SARS医院感染的预防和控制措施的探讨[J].中华医院感染学杂志,2004,14(1):71-73. 被引量:13
  • 2李坤成,刘玉清,孙立忠,卞晓明,常谦.马凡综合征心血管病变的MRI诊断[J].中华放射学杂志,1996,30(7):468-471. 被引量:8
  • 3Preston ll, Epstein M. Ischemic renal disease: an emerging cause of chronic renal failure and end--stage renal disease. J Hypertens 1997, 15: 1365-1377. 被引量:1
  • 4Vasbinder GB, Nelemans PJ, Kessels hG, et al. Diagnostic tests for renal artery stenosis in lzatients suspected of having renovascular hypertension: a meta-analysis. Am Intern tged 2001, 135: 401-411. 被引量:1
  • 5Schoenberg SO, Rieger J, Johannsan LO, et al. Diagnosis of renal artery stenosis with magnetic resonance angiography:update 2003. Nephrol Dial Transplant 2003, 18: 1252-1256. 被引量:1
  • 6Kay J. Nephrogenic systemic fibrosis: a gadelinium-associated fibrosing disorder in patients with renal dysfunctiom Ann Rheum Dis. 2008, 67(3):66-9. 被引量:1
  • 7Potthast S, Maki JH. Non--contrast--enhanced MR imaging of the renal arteries. Magn Reson Imaging Clin N Am. 2008, 16(4): 573-84, vii. 被引量:1
  • 8李坤成.MRI常规技术及新技术.北京:中国人口出版社,2004:63. 被引量:1
  • 9Scheffler K, Heid O, Hennig J. Magnetization preparation during the steady state: fatsaturated 3D TrueFISP. Magn Resort Med 2001, 45: 1075--1080. 被引量:1
  • 10Loubeyre P, Revel D, Garcia P, et al. Screwing patients for regal artery stenosis:value of three--dinensional time-of-flight MR angiography. AIR Am J Roentgenol 1994, 162: 847-852. 被引量:1

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部