用正庚烷作内标物,10%PEG20M+1%NaOH/酸洗201红色担体作固定相,氢焰检测,对酯化反应液中的甲基丙烯酸甲酯(MMA)及甲醇进行定量分析。测得MMA和MeOH的校正因子分别为1.65和4.10,其相对误差分别小于1.5%和2.5%。方法便捷、可靠,值得推广应用。
A fast, simple and accurate gas chromatographic method is established for determining the content of methyl methacrylate (MMA) and methanol in the esterification mixture of methacrylic acid with methanol in the presence of sulfuric acid. In the measurement, polyethylene glycol20M/sodium hydroxide was adopted as liquid phase, coated on the acid washed 201 pink support. n Heptane was used as the internal standard and the correction factors of MMA and methanol obtained were 1.65 and 4.10, respectively. It is significant for this method to be used to contol MMA production by acetone cyanohydrin method and to improve the production technology.