摘要 基于相关性能测试标准和JJF 1059-1999规范,对整体水源热泵样机制冷量测试结果的不确定度进行了分析,建立了空气侧和水侧计算数学模型,对A类和B类不确定度进行了分别评定,结果表明,机组该次测量的不确定相对值为2%。讨论干球温度、湿球温度、喷嘴直径、压差、大气压力、水温、流量等参数对制冷量测量不确定度的影响,提出了对温度测量回路进行一体化标定的建议,为提高试验系统的测试水平提供了参考。 Based on standards GB/T 19409-2003 and JJF 1059-1999, uncertainty in integral water-souree heat pump cooling capacity measurement is analyzed. Calculation model for air-side and water-side test are established, and A-type and B-type un- certainty are evaluated respectively. Conclusion indicates that relative uncertainty of this measurement is 2%. Main influence fac- tors on refrigeration volume measurement, such as dry-bulb temperature, wet-bulb temperature, nozzle diameter, pressure differ- ence, atmospheric pressure, water temperature, flow, etc. , are discussed. Temperature measurement channel integral calibration is recommended, and the advices are helpful for accuracy enhancement of test system.
出处 《流体机械》 CSCD 北大核心 2008年第9期56-58,41,共4页 Fluid Machinery
基金 国家科技支撑计划资助项目(2006BAJ01A10)
关键词 整体水源热泵 测量 制冷量 不确定度 integral water-source heat pump measurement cooling capacity uncertainty
  • 相关文献

参考文献6

二级参考文献9

  • 1JJF1059-1999.测量不确定度评定与表示[S].[S].,.. 被引量:779
  • 2GB5773—86.容积式制冷压缩机性能试验方法[S].[S].,.. 被引量:1
  • 3刘智敏.不确定度及实践[M].北京:中国标准出版社,1999.. 被引量:2
  • 4GB5773-86.容积式制冷压缩机性能试验方法[S].[S].,.. 被引量:3
  • 5刘智敏.不确定度及实践[M].北京:中国标准出版社,1999.. 被引量:1
  • 6ISO917-1987,Testing of refrigerant compressors[S]. 被引量:1
  • 7GB5773-1986.容积式制冷压缩机性能试验方法[S].[S].,.. 被引量:1
  • 8沈志光.制冷工质热物理性质标和图[M].北京:机械工业出版社,1983.. 被引量:1
  • 9QC/T657-2000.汽车空调制冷装置试验方法[S].[S].,.. 被引量:4

共引文献823

同被引文献32

引证文献5

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部