期刊文献+

基于光纤环形衰荡腔的甲烷传感研究 被引量:3

Methane Sensing Research Based on Fiberloop Ring-down Cavity
下载PDF
导出
摘要 提出一种基于腔衰荡光谱技术的新型光纤甲烷传感方法,与传统的甲烷传感方式相比,它可以通过测量信号的相位移动来测量气体的浓度。实验中采用了环形的光纤结构,避免了小型渐变折射率透镜构成的微型气室产生的二次噪声,提高了系统的灵敏度。结果表明,该系统可以应用于低浓度气体的在线检测。 A novel methane sensing method based on cavity ring-down spectroscopy (CRDS) was proposed. Compared with the traditional methane sensing method, this scheme measured methane concentration by measuring phase shift of the experiment signal. In the experiment, the fiber-loop was used, which can reduce the second noise of GRIN cell and improve the system sensibility. The experiment results show that the system can be used in online measurement of low concentration gas.
作者 魏冬明
机构地区 燕山大学
出处 《仪表技术与传感器》 CSCD 北大核心 2008年第9期9-10,20,共3页 Instrument Technique and Sensor
关键词 瓦斯爆炸 甲烷 光纤环形衰荡腔 衰荡时间 相位检测 gas explosion methane fiber-loop ring-down cavity ring-down time phase detection
  • 相关文献

参考文献10

  • 1CULSHAW B, STEWART G, DONG F,et al. Fibre optic techniques for remote spectroscopic methane detection-from concept to system realization. Sensors and Actuators B, 1998,51 (1 -3) :25 -37. 被引量:1
  • 2罗勇,毛晓波,黄俊杰.红外检测瓦斯传感器的设计与实现[J].仪表技术与传感器,2007(8):4-6. 被引量:32
  • 3WILLER U, SARAJI M, KHORSANDI A, et al. Near-and mid-infrared laser monitoring of industrial processes environment and security applications. Optics and Lasers in Engineering, 2006,44(7 ) :699 - 710. 被引量:1
  • 4ROMANINI D, DUPRE P,JOST R. Non-linear effects by continuous wave cavity ringdown spectroscopy in jet-cooled NO2. Vibrational Spectroscopy, 1999,19 ( 1 ) :93 - 106. 被引量:1
  • 5PETTERSSON A, LOVEJOY E R, BROCK C A, et al. Measurement of aerosol optical extinction at 532nm with pulsed cavity ring down spectroscopy. Journal of Aerosol Science, 2004,35 ( 8 ) :995 - 1011. 被引量:1
  • 6GUPTA M, JIAO H, O'KEEFE A. Cavity-enhanced spectroscopy in optical fibers. Optics Letters, 2002,27(21 ) :1878 -1880. 被引量:1
  • 7TARSA P B, RABINOWITZ P, LEHMANN K K. Evanescent field absorption in a passive optical fiber resonator using continuous-wave cavity ring-down spectroscopy. Chemical Physics Letters, 2004,383 ( 3 - 4) :297 - 303. 被引量:1
  • 8LOOCK H P. Ring-down absorption spectroscopy for analytical microdevices. Trends in Analytical Chemistry, 2006,25 ( 7 ) :655 - 664. 被引量:1
  • 9ENGELN R, HELDEN G V, BERDEN G, et al. Phase shift cavity ring down absorption spectroscopy. Chemical Physics Letters, 1996, 262(1 -2) :105 - 109. 被引量:1
  • 10CHAN K, ITO H,INABA H. An optical-fiber-based gas sensor for remote absorption measurement of low-level CH4 gas in the near-infrared region. Journal of lightwave technology, 1984, LT-2 (3) :234 - 237. 被引量:1

二级参考文献7

共引文献31

同被引文献29

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部