期刊文献+

污水厂高浓度氯离子出水中COD测定方法的研究 被引量:7

Study on Determination of COD in Effluent with High Chlorine Ion from Sewage Treatment Plants
下载PDF
导出
摘要 针对污水处理厂出水COD测量中的氯离子干扰问题,从测定原理、消除效果及适用范围等方面对常用的几种标准方法进行了比较,并对筛选出的适用方法进行了实践。结果表明,低浓度氧化剂法、氯气校正法的结果相近,是测定污水厂高浓度氯离子出水中COD的可行方法。 Concerning the disturbance of chlorine ion in determination of COD in effluent from sewage treatment plants, the conventional methods to eliminate the disturbance are compared in terms of the determination principles, the elimination effects, the application scopes and so on. The selected methods are applied in practice. The results indicate that with the similar results, the chlorine emendation method and the low-concentration oxidant method are feasible for determination of COD in effluent with high chlorine ion from sewage treatment plants.
出处 《中国给水排水》 CAS CSCD 北大核心 2008年第15期66-68,共3页 China Water & Wastewater
关键词 化学需氧量 氯离子 低浓度氧化剂法 氯气校正法 COD chlorine ion low-concentration oxidant method chlorine emendation method