蒸发式冷凝空调的性能强化及应用研究 被引量:2

Enhanced performance and application of evaporative condensing to air conditioning
下载PDF
导出
摘要 提出了蒸发式冷凝器用于集中空调系统的方法,分析了3种蒸发式冷凝空调的特点。实验结果表明,扭曲管相对于圆管和椭圆管,可平均分别提升机组制冷量4.2%~5.3%和2.4%~3.0%,减少压缩机功耗14.1%~16.0%和6.5%~9.8%;在实际应用中,地区气候差异的影响不超过10%,蒸发式冷凝空调可比其他冷凝式空调体积减小20%以上,节能25%以上。 Proposes a new central air conditioning system involving the evaporative condenser, and analyses the characteristics of three kind of evaporative condensing air conditioning systems. The test results show that the refrigeration capacity of the system with twisted tube is 4.2 to 5.3 percent and 2.4 to 3.0 percent better than those with round tube and oval tube respectively, while the power consumed by the compressor 14.1 to 16.0 percent and 6.5 to 9.8 percent less, and the total performance of the new air conditioning system in the South region has a decrease no more than 10% compared to the North region, and the volume of new evaporative condenser is smaller by over 20 percent than air condensers or water condensers, while energy saving is above 25 percent.
出处 《暖通空调》 北大核心 2008年第5期56-59,89,共5页 Heating Ventilating & Air Conditioning
基金 教育部博士点基金项目(编号:20050561017) 粤港关键领域重点突破项目(编号:TC05B372-8) 广州市科技成果转化项目(编号:2007C13 G0041)
关键词 空调 节能 蒸发式冷凝器 冷却 应用 air conditioning, energy saving, evaporative condenser, cooling, application
  • 相关文献

参考文献5

二级参考文献21

共引文献146

同被引文献14

引证文献2

二级引证文献18