期刊文献+

翻转线圈系统在波荡器积分场测量中的应用 被引量:4

Application of flipping coil system to integrated magnetic field measurements in undulators
下载PDF
导出
摘要 为了更有效地测量用于上海同步辐射光源波荡器的积分场误差,在已有的伸展线磁测系统的基础上研制了一套翻转线圈磁测系统,该系统的运动控制、数据采集和数据分析处理均可自动完成。在利用这套磁测系统测量3.4×10-6T.m磁场积分时获得高于1×10-6T.m的测量精度,初步的实验结果表明这套波荡器积分磁场测量系统具有测量精度好、速度快的特点,与已有的伸展线磁测系统、平移线圈磁测系统和霍尔点测系统相比,它更适合于测量波荡器的一、二次场积分和多极场分量。 In order to characterize the undulators at Shanghai Synchroton Radiation Facility(SSRF), a flipping coil magnetic field integral measurement system for the measurement of both first and second magnetic field integral distributions and integrated multipole errors in undulators has been developed recently. The system can automatically finish motion control, data acquisition and data analysis. The main features of this system are their high speed of measurement, high precision. Initial results demonstrated that the system achieves a system measurement precision of 1 × 10^-8 T · m in a field integral measurement of 3.4 × 10^-4 T · m. The system is efficient enough to finish the measurements of magnetic field integral in undulators.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2008年第5期871-875,共5页 High Power Laser and Particle Beams
关键词 波荡器 磁场测量 翻转线圈 MAGIC FINGERS 积分场误差 同步辐射光源 Undulator Magnet field measurement Flipping coil Magnetic field integral Magic fingers Synchroton radiation facility
  • 相关文献

参考文献10

  • 1Hwang C S, Fan T C, Lin F Y, et al. Advanced field measurement method with three orthogonal Hall probes for an elliptically polarizing undulator[J]. J Synchrotron Rad, 1998,5 :471-474. 被引量:1
  • 2Zangrando D, Walker R P. A stretched wire system for accurate integrated magnetic field measurements in insertion devices[J].Nucl Instr and Meth in Phys Res, 1996,376(2):275-282. 被引量:1
  • 3Hwang C S, Fan T C, Lin F Y, et al. A long loop coil system for insertion device magnet measurement[J]. Instrumentation and Measurement ,2003,52(3) :865- 870. 被引量:1
  • 4Xu J Z, Vasserman I. A new magnetic field integral measurement system[C]//Particle Accelerator Conference,PAC 2005. 2005:1808-1810. 被引量:1
  • 5贾启卡.波荡器位相误差对自由电子激光小信号增益的影响(英文)[J].强激光与粒子束,2002,14(2):165-168. 被引量:4
  • 6汪涛,贾启卡.上海深紫外自由电子激光装置波荡器磁场调整[J].强激光与粒子束,2007,19(12):2083-2086. 被引量:4
  • 7刘君华主编,郭会军等编著..基于LabVIEW的虚拟仪器设计[M].北京:电子工业出版社,2003:403.
  • 8Hoyer E. Multiple trim magnets or magic fingers for insertion device field integral correction[J]. Rev Sci Instr, 1995,66(2) :1901-1903. 被引量:1
  • 9马明建,周长城编著..数据采集与处理技术[M].西安:西安交通大学出版社,1998:301.
  • 10林国荣编著,张友德改编..电磁干扰及控制[M].北京:电子工业出版社,2003:323.