期刊文献+

基于μTAS系统多参量血液分析生物传感器与测量仪器的研究

Research on a biosensor for blood analysis based on μTAS and measuring apparatus
下载PDF
导出
摘要 研制出一种基于μTAS系统的血液分析型医用多参量测量的生物传感测量仪器.该传感器采用IDA结构的微电极阵列,分别固定上不同的酶,当工作区中的微电极上滴上少许血样,通过检测微电极上生化反应所产生的微电流,可同时测试出血液中血糖、胆固醇、酮体和乳酸的浓度.测量仪器的电流测量范围0~40μA,灵敏度为1 nA.该系统经北京医疗器械研究所测试,取得较好的实验结果. A multi-parameters μTAS biosenor used for the blood analysis in medicine is researched. Based on μTAS technology, the interdigital array (IDA)microelectrodes are designed and fabricated. Then the four groups of microelectrodes are respectively glucose the different enzyme. When a little blood is dropped in the work area, four parameters concentration including Blood sugar, Cholesterol, Acetone body and Lactic acid are measured through detecting reactive currents in IDA microelectrodes. The measure instrument achieves 40 μA of full scale and 1 nA of sensitivity. The experimental results tested by Beijing Academy of the Medical Instruments are satisfactory.
出处 《天津工业大学学报》 CAS 2008年第1期46-49,59,共5页 Journal of Tiangong University
基金 天津市科技攻关培育项目(043100911)
关键词 生物传感器 微全分析系统 IDA微电极 血液分析 测量仪器 biosensor μTAS(micro total analysis system) IDA microelectrode blood analysis measuring apparatus
  • 相关文献

参考文献9

  • 1MANZ A. Miniaturized total chemical analysis systems: A novel concept for chemical sensing [J]. Sensors and Actuators B Chemical, 1990, 1 (1) : 244-248. 被引量:1
  • 2张先恩..生物传感器[M],2006.
  • 3HOLGER Becker, ANDREAS Manz. Miniaturized total analysis systems: Microsystem technology entering the life sciences [J]. Science Progress, 1996, 79(1 ): 49-63. 被引量:1
  • 4LI G, MAN Z, WANG Y. A new handheld biosensor for monitoring blood ketones [J]. Sensors and Actuators B Chemical, 2005,109(2) : 285-290. 被引量:1
  • 5GUAN W J, LI Y, CHEN Y Q. Studies of carbon nanotube - enzyme complex system [J]. Biosensors and Bioelectronics, 2005,21 (4) :495-500. 被引量:1
  • 6AOKI K,MORITA M,NIW A, et al. Quantitative analysis of reversible difusion-controlled currents of redox soluble species at interdigitated array electrodes under steady state conditions [J]. J Electroanal Chem, 1988, 256: 269-282. 被引量:1
  • 7COHEN Adam E, KUNZ Roderick R. Large-area interdigitated array microelectrodes for electrochemical sensing[J]. Sensors and Actuators B, 2000, 62: 23-29. 被引量:1
  • 8PAESCHKE M, WOLLENBERGER U, KOHLER C, et al. Properties of interdigital electrode arrays with different geometries [J]. Analytica Chimica Acta, 1995, 305 : 126-136. 被引量:1
  • 9梁争喜,陈才和,刘杰,童峥嵘.多参数血液分析型生物传感器的研究[J].传感技术学报,2006,19(1):60-63. 被引量:7

二级参考文献4

  • 1Cohen Adam E,Kunz Roderick R.Large-Area Interdigitated Array Microelectrodes for Electrochemical Sensing[J].Sensors and Actuators B,2000,62:23-29. 被引量:1
  • 2Aoki K,Morita M,Niwa O,Tabei H.Quantitative Analysis of Reversible Diffusion-Controlled Currents of Redox Soluble Species at Interdigitated Array Electrodes Under Steady-State Conditions[J].J Electroanal.Chem.256 (1988) 269-282. 被引量:1
  • 3Paeschke M,Wollenberger U,Kohler C,Lisec T,Schnakenberg U,Hintsche R.Properties of Interdigital Electrode Arrays with Different Geometries[J].Analytica Chimica Acta,1995,305:126-136. 被引量:1
  • 4冉旭,冉均国,苟立,王方瑚.壳聚糖凝胶固定葡萄糖氧化酶制备酶电极的工艺[J].食品与发酵工业,2003,29(8):32-35. 被引量:4

共引文献6