摘要 目的探讨在心律失常患者冠状动脉CTA数据后处理重建过程中,ECG编辑功能对修正相位的应用价值。方法69例心律失常的患者在我院接受了冠状动脉CTA检查,所有患者的扫描数据均因心律不齐而采用了ECG编辑软件进行处理,比较处理前、后的图像质量,评价ECG编辑功能对修正不同类型心律失常相位重建的应用价值。结果69例患者中,偶发房早24例,偶发室早33例,缓慢型房颤5例,快速率房颤3例,频发室早3例,Ⅱ度Ⅰ型窦房阻滞1例。经ECG编辑处理后,图像质量达到优者26例,占38%;良者32例,占46%;中者5例,占7%。图像质量差者6例,占9%。结论ECG编辑功能对改善偶发早搏(房早、室早)、较慢心率下(≤70次/分)房颤患者的CTA图像质量有较大帮助,但对频发早搏、较快心率下的房颤无明显作用。 Objective To discuss the applied value of ECG editing function in image processing reconstruction of coronary CT angiography with arrhythrnia. Methods Sixty-nine patients who having arrhythmia were examined. Coronary CT angiography was obtained at Philips Brilliance 64-slice spiral CT by using ECG editing software. The image quality of the before and after processing was compared. The applied value of ECG editing software was evaluated in different heart rate. Results Among 69 patients, casually premature artial contractions (PAC) 24 cases, casually premature ventricular contractions (PVC) 33 cases, chronic artrial fibrillation 5 cases, rapid artrial fibrillation 3 cases, frequency PVC 3 cases, Ⅱ degree of Ⅰ type sinus block 1 case. After ECG editing, image quality fully improved 26 cases (38%), significantly improved 32cases (46%), commonly improved 5 cases (7 %), no improved 6 cases (9 %). Conclusion The CTA image quality can be improved in casually PAC and PVC under slower heart rate (≤70/pm) with ECG editing function. It was no improved in frequency PAC and PVC under rapid heart rate.
出处 《中国医学影像技术》 CSCD 北大核心 2008年第1期92-94,共3页 Chinese Journal of Medical Imaging Technology
基金 上海市浦东新区社发局科技项目(PW2004-A24)
关键词 CT血管造影 冠状动脉 心率 图像处理 CT angiography Coronary artery Heart rate Image processing
  • 相关文献

参考文献5

二级参考文献13

  • 1姜荣,吴晓华,贺文.心率波动对多层螺旋CT冠脉造影图像质量的影响[J].中国医学影像技术,2004,20(10):1574-1576. 被引量:49
  • 2龚艳君,霍勇.64排CT冠状动脉成像的临床应用现况[J].中国介入心脏病学杂志,2005,13(6):416-416. 被引量:26
  • 3American Heart Association.Heart disease and stroke statistical-2005 update[R].Dallas,Tex:American Heart Association,2005. 被引量:1
  • 4Flohr T,Schoepf UJ,Kuettner A,et al.Advances in cardiac imaging with 16-section CT systems[J].Acad Radiol,2003,10(4):386-401. 被引量:1
  • 5Adey H,Ballantyne DA,Bostock MI,et al.The prevalence of disturbance of cardiac rhythm in healthy New Zealand adults:a pilot study[J].N Z Med J,1978,88(625):433-435. 被引量:1
  • 6Clarke JM,Hamer J,Shelton JR,et al.The rhythm of the normal human heart[J].Lancet,1976,1(7984):508-512. 被引量:1
  • 7Nieman K,Rensing B,van Geuns R,et al.Non-invasive coronary angiography with multislice spiral computed tomography:impact of heart rate[J].Heart,2002,88(5):470-474. 被引量:1
  • 8Hoffmann MH,Shi H,Manzke R,et al.Noninvasive coronary angiography with 16-detector row CT:effect of heart rate[J].Radiology,2005,234(1):86-97. 被引量:1
  • 9Nakanishi T,Kayashima Y,Inoue R,et al.Pitfalls in 16-detector row CT of the coronary arteries[J].Radiographics,2005,25(2):425-440. 被引量:1
  • 10萧毅,田建明,王培军,秦永文,薛宏,李晓兵,王敏杰,左长京,曾浩,崔恒武.多层螺旋CT冠状动脉造影的扫描技术及临床应用[J].中华放射学杂志,2002,36(4):357-361. 被引量:144