摘要 通过对重庆市既有大中型商场建筑空调能耗数据的调查研究分析,发现既有商场建筑空调系统中各个部分存在的问题如设计不合理,设备选型过大,输送设备配置不合理,运行管理方式落后等。在此基础上指出目前重庆市既有商场建筑空调系统能耗较高产生的原因,并针对问题进行其节能潜力分析,提出适宜重庆市既有商场建筑的节能改造的合理化建议。 To investigate the energy consumption situation of subsistent store buildings, problems of each part of the present air-conditioning systems in large and medium scale of subsistent store buildings were found out, such as irrational design, too high equipment lectotype, illegitimate conveyer equipments, poor operation and management etc.. Based on the applying status of air-conditioning, the causes of the air-conditioning system energy consumption of large and medium scale of subsistent store buildings in Chongqing were pointed out. And the energy saving potential of central air-conditioning system was analyzed. Some reasonable suggestions for the energy saving reconstruction of these stores were put forward.
出处 《建筑节能》 CAS 2008年第2期1-4,共4页 BUILDING ENERGY EFFICIENCY
关键词 既有大中型商场建筑 集中空调能耗 冷却塔 large and medium scale of subsistent store buildings energy consumption of air-conditioning system cooling tower
  • 相关文献

参考文献1

  • 1[1]2007年中围可再生能源市场分析及投资咨询报告[EB/OL].http://www.ocn.com.cn/reports/2006067 kezaishengnengyuan.htm(A Report of Analysis and Investment Consult About Chinese Regenerative Energy Market In 2007[EB/OL].http://www.ocn.com.cn/reports/2006067 kezaishengnengyuan.him) 被引量:1