期刊文献+

消化道无创诊疗微系统的无线供能技术的研究 被引量:1

Study on a Wireless Energy Transmission System for the Non-Invasive Examination Micro System inside Alimentary Tracts
下载PDF
导出
摘要 报道了一种消化道微创诊疗微系统的无线体外供能装置,它主要由利用锁相环的自动频率跟踪电路和采用移相的调功电路构成。实验表明,该供能装置能自动频率跟踪和调节输出功率,使接收能量稳定。 A wireless energy transmission system for the MEMS system inside alimentary tracts is reported here in the paper. It consists of an automatic frequency tracking circuit of phase lock loop and phase shift PWM control circuit. Experimental results show that the energy transmission system is capable of automatic frequency-tracking and transmission power-adjusting and has stable received energy.
出处 《中国医疗器械杂志》 CAS 2008年第1期19-22,49,共5页 Chinese Journal of Medical Instrumentation
基金 国家"863"计划(2006AA04Z368) 国家自然科学基金项目(30570485) 上海市自然科学基金项目(06ZR14046)联合资助
关键词 无创诊疗微系统 无线供能 锁相环 频率跟踪 移相PWM non-invasive examination micro system, wireless energy transmission, phase lock loop, frequency-tracking, phase shift PWM
  • 相关文献

参考文献8

二级参考文献13

  • 1OKUNOA. FeasibleDevelopmentofSofi-Switches SITInverter with Load-Adaptive Frequency-tracking Control Scheme for Induction Heating [J]. IEEE Transactions on Industry Applications, 1998, 34 (4): 713-718. 被引量:1
  • 2JAI P A. Power Electronic Systems Theory and Design [M].Beiiing: Tsinghua University Press, Prentice - hall. 2001. 被引量:1
  • 3刘京南 王成华.电子电路基础[M].北京:电子工业出版社,2002.. 被引量:1
  • 4魏立君 韩华琦.CMOS 4000系列60中常用集成电路的应用[M].北京:人民邮电出版社,1996.. 被引量:1
  • 5lkuta K.The application of the micro/miniature mechatronics to medical robotics.IEEE International Workshop on Intelligent Robots,Center for Robotic Systems in Microelectronics.California,USA:University of California,1988 被引量:1
  • 6Hoeg HD,Slatkin AB,Burdick JW.Biomechanical modeling of the small intestine as required for design and operation of robotic endoscope.Proceeding of 2000 IEEE International Conference on Robotics & Automation.San Francisco,CA:IEEE,2000 被引量:1
  • 7Carrozza MC,Lencioni L,Magnani B.A microrobot for colonoscopy.IEEE Seventh International Symposium on Micro Machine and Human Science.October 2; Japan,Nagoya:Municipal Industrial Research Institute,1997 被引量:1
  • 8Young ML,Jinhee L,Jisang P.A self-propelling endoscopy system.Proceeding of the 2001 IEEE/RSJ.Maui Hawii,USA:IEEE,2001 被引量:1
  • 9Ikeuchi K,Yoshinaka K,Hanshimoto S.Locomotion of medical micro robot with spiral ribs using mucus.IEEE Seventh International Symposium on Micro Machine and Human Science.Japan Nagoya:Municipal Industrial Research Institute,1996 被引量:1
  • 10Dario P,Carrozza MC,Pietrabissa A.Development and In-Vitro testing of a miniature robotic system for colonoscopy.Journal of Computer Aided Surgery,1999,4:1-14 被引量:1

共引文献53

同被引文献8

  • 1张思杰,彭承琳,郑小林,刘艳,皮喜田,侯文生.基于MEMS技术的胃肠道无线内窥镜的研究[J].仪器仪表学报,2005,26(7):681-683. 被引量:3
  • 2LENAERTS B, PUERS R. Inductive powering of a freely moving system [J]. Sensors and Actuators a-Physical, 2005,123(124):522-530. 被引量:1
  • 3RYU M, KIM J D, CHIN H U, et al. Three-dimensional power receiver for in vivo robotic capsules [J]. Medical & Biological Engineering & Computing, 2007, 45: 997- 1002. 被引量:1
  • 4DELVAUX M, GAY G. Capsule endoscopy: technique and indications[J]. Best Practice & Research in Clinical Gastroenterology, 2008,22(5):813-837. 被引量:1
  • 5LENAERTS B, PUERS R. An inductive power link for a wireless endoscope[J]. Biosensors & Bioelectronics, 2007,22(7): 1390-1395. 被引量:1
  • 6SHIBA K, SHU E, KOSHIJI K, et al. Transcutaneous energy transmission system for a totally implantable total artificial heart: Design and in vivo evaluation of the energy backup system [J]. Japanese Journal of Artificial Organs, 2000,29(1):24-30. 被引量:1
  • 7TSAI C C, CHEN B S, TSAI C M. Design of wireless transcutaneous energy transmission system for totally artificial hearts[J]. 2000 Ieee Asia-Pacific Conference on Circuits and Systems, 2000:646-649. 被引量:1
  • 8马官营,颜国正,何秀.基于电磁感应的消化道内微系统的无线供能[J].上海交通大学学报,2008,42(5):798-802. 被引量:17

引证文献1

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部