摘要 目的探讨下腔静脉滤器置入术(IVCF)预防致命性肺动脉栓塞(PE)的疗效、相关并发症及处理。方法经股静脉途径放置下腔静脉滤器96例。结果术后随访4~36个月。96例IVCF无一例出现致命性肺栓塞,17例出现相关的并发症。结论下腔静脉滤器可以有效预防致命性肺动脉栓塞,并发症的发生率较高,相关并发症可以有效预防和处理。 Objective To investigate the effects of filter placement for inferior vena cava in prevention of fatal pulmonary embolism (PE)and the treatment of postoperative complications. Methods Inferior vena cava filters were placed in 96 patients by the way of femoral vein. Results All the patients were followed up for 4 - 36 months after the procedure without fatal pulmonary embolism occurrance in the 96 patients, but with only 17 correlated complications. Conclusion Inferior vena cava filter placement is easy and safe which can prevent the high complication incidence of fatal pulmonary arterial embolism with further more effective prevention and management of other correlative complications.
出处 《介入放射学杂志》 CSCD 2008年第1期19-21,共3页 Journal of Interventional Radiology
关键词 下腔静脉滤器置入术 致命性肺动脉栓塞 并发症 Inferior vena cava filter Fatal pulmonary embolism Complication
  • 相关文献

参考文献8

二级参考文献39

  • 1马和平,张学军,朝鲁孟,甄彦利,李银光,梁秀琴,周群慧,顾苏滨,刘鹏芝,王虹.在深静脉血栓—肺栓塞病程中腔静脉滤器的应用价值分析[J].内蒙古医学杂志,2004,36(10):729-731. 被引量:1
  • 2任安,姜卫剑,黄振国,陆立,张雪哲,卢延.国人肾下段下腔静脉测量及分析[J].中华放射学杂志,1996,30(2):109-112. 被引量:12
  • 3马和平,张学军,朝鲁孟,甄彦利,苏俐,张伟.下腔静脉滤器置放术在深静脉血栓-肺栓塞演变中的临床应用[J].中国介入影像与治疗学,2006,3(5):325-328. 被引量:4
  • 4[1]Millward SF, Peterson RA, Moher D, et al. LGM(Vena Tech) venacava filter: experience at a single institution[J]. J Vasc Interv Radiol,1994, 5(2): 351-356. 被引量:1
  • 5[2]Athanasoulis CA, Kaufman JA, Halpern EF, et al. Inferior vena cava filters: review of a 26-year single-center clinical experience[J]. Radiology, 2000, 216(1):54-66. 被引量:1
  • 6[3]David W, Gross WS, Colaiuta E, et al. Pulmonary embolus after vena cava filter placement[J]. Am Surg, 1999, 65(4): 341-346. 被引量:1
  • 7[4]Crochet DP, Stora O, Ferry D, et al. Vena Tech-LGM filter: long-term results of a prospective study[J]. Radiology, 1993, 188(3): 857-860. 被引量:1
  • 8[5]Poletti PA, Becker CD, Prina L, et al. Long-term results of the simon nitinol inferior vena cava filter[J]. Eur Radiol, 1998, 8(2): 289-294. 被引量:1
  • 9[6]Korbin CD, Reed RA, Taylor FC, et al. In vitro flow phantom analysis and clot-capturing ability of incompletely opened Vena Tech-LGM vena cava filters[J]. Cardiovasc Intervent Radiol, 1993, 16(1): 3-6. 被引量:1
  • 10[7]Millward SF, Marsh JI, Pon C, et al. Thrombus-trapping efficiency of the LGM(Vena Tech) and Titanium Greenfield filters in vivo[J]. J Vasc Interv Radiol, 1992, 3(1): 103-106. 被引量:1

共引文献59

同被引文献135

引证文献24

二级引证文献51

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部