摘要
通过对汉川电厂实际燃煤的分析,计算说用了煤质变化对炉膛出口烟温、制粉系统出力产生的不良影响,从而说明锅炉出力不足的原因,并特别提出了经制煤质的变化范围和适当提高煤粉细度以解决锅炉出力不足问题的措施。
The reason why the boiler rating fell short of its rating was found after having peformed an analysis of the actual coal burnt by Hanchuan power plant,followed by some calculations,which showed what harmful influence variations of coal categories has on the furnace' s exit gas temperature and mill output. For solving the problern of the boiler' s inadequate output,the paper stresses the importance ol checking the range of category variation of coal supplied and appropriately using finer coal granules.
出处
《发电设备》
1997年第1期2-4,共3页
Power Equipment