期刊文献+

Evaluation and optimization of secondary water supply system renovation 被引量:5

Evaluation and optimization of secondary water supply system renovation
下载PDF
导出
摘要 Due to pollution in second water supply system (SWSS),nine renovation alternative plans were proposed and com-prehensive evaluations of different plan based on Analytical Hierarchy Process (AHP) were presented in this paper. Comparisons of advantages and disadvantages among the plans of SWSS renovations provided solid foundation for selecting the most appro-priate plan for engineering projects. In addition,a mathematical model of the optimal combination of renovation plans has been set up and software Lingo was used to solve the model. As a case study,the paper analyzed 15 buildings in Tianjin City. After simulation of the SWSS renovation system,an optimal scheme was obtained,the result of which indicates that 10 out of those 15 buildings need be renovated in priority. The renovation plans selected for each building are the ones ranked higher in the com-prehensive analysis. The analysis revealed that the optimal scheme,compared with two other randomly calculated ones,increased the percentage of service population by 19.6% and 13.6% respectively,which significantly improved social and economical benefits. Due to pollution in second water supply system (SWSS), nine renovation alternative plans were proposed and comprehensive evaluations of different plan based on Analytical Hierarchy Process (AHP) were presented in this paper. Comparisons of advantages and disadvantages among the plans of SWSS renovations provided solid foundation for selecting the most appropriate plan for engineering projects. In addition, a mathematical model of the optimal combination of renovation plans has been set up and software Lingo was used to solve the model. As a case study, the paper analyzed 15 buildings in Tianjin City. After simulation of the SWSS renovation system, an optimal scheme was obtained, the result of which indicates that 10 out of those 15 buildings need be renovated in priority. The renovation plans selected for each building are the ones ranked higher in the com- prehensive analysis. The analysis revealed that the optimal scheme, compared with two other randomly calculated ones, increased the percentage of service population by 19.6% and 13.6% respectively, which significantly improved social and economical benefits.
出处 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第9期1488-1494,共7页 浙江大学学报(英文版)A辑(应用物理与工程)
基金 Project (No.033113111) supported by Tianjin Science Association Key Project,China
关键词 Secondary water supply system (SWSS) Renovation plan Analytical Hierarchy Process (AHP) Hierarchical model OPTIMIZATION 次级给水系统 层次分析法 层次模型 最优化
  • 相关文献

参考文献4

二级参考文献8

共引文献21

同被引文献52

引证文献5

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部