摘要 通过实例介绍了离子色谱在火力发电厂的水汽质量异常分析中的应用,利用离子色谱的检测数据能够及时发现水汽品质的异常情况,便于问题分析和及时采取对策,从而防止因水汽质量恶化引起的腐蚀、结垢、积盐事故的发生。 Abstract:The application of ion chromatography on the abnormal steam-water quality analysis in thermal power plant was introduced in this paper by some examples. Using detection data of ion chromatography could discover abnormal states of steam-water in time, and was convenient for problem analysis and taking countermeasures. Thus corrosion, scaling and mineral deposition caused by steam-water worsening were prevented.
出处 《华北电力技术》 CAS 2007年第8期34-36,共3页 North China Electric Power
关键词 离子色谱 火力发电厂 水汽品质异常 监督 ion chromatography thermal power plant abnormal steam-water quality supervision