摘要 叙述从衍射数据的质量来评估X射数粉末衍射仪的性能的观点和方法。主要衍射数据为衍射峰的位置(布拉格角2θ),衍射的强度(衍射峰的积分强度I和各测量点强度Y)和衍射峰的峰形(半峰宽H与分辨率)。 The view and the processes which were based upon the qualities of the diffraction data measured to estimate the performances of a X-ray powder diffractometer were presented. The main diffraction data are the Bragg angles (2 θ ), the peak intensities (I or Y ) and the peak profiles (FWHM and pattern resolution).
作者 马礼敦
出处 《上海计量测试》 2007年第2期10-15,共6页 Shanghai Measurement and Testing
关键词 X射线粉末衍射仪 性能 评估 衍射数据 performance, estimation, X-ray powder diffractometer
  • 相关文献

参考文献10

  • 1[5]International Centre for Diffraction Data.Powder Diffraction File.Newtown Square,USA. 被引量:1
  • 2[6]National Institute of Standards and Technology.Certificate standard reference material 640c silicon powder,line position and line shape standard for powder diffraction.Gaithersburg,USA:2000. 被引量:1
  • 3[7]National Institute of Standards and Technology.Certificate standard reference material 1976,Instrument Sensitivity Standard for X-ray Powder Diffraction.Gaithersburg,USA:1991. 被引量:1
  • 4[8]Schreiner W N,Jenkins R.Request for comments□A reference standard for determining instrumental response for X-ray powder diffraction.Powder Diffr.1990,5(4):204~205. 被引量:1
  • 5马礼敦编著..近代X射线多晶体衍射 实验技术与数据分析[M].北京:化学工业出版社,2004:612.
  • 6[11]Blanton T N,Schreiner W N,Dann J N.JCPDS-International Centre for Diffraction Data.Statistical process control method development.Powder Diffr.1993,8(4):229~235. 被引量:1
  • 7[12]American Society for Quality Control.Glossary & tables for statistical quality control.Milwaukee:ASQC Quality Press,1983. 被引量:1
  • 8[13]Peplinski B,Wenzel J.Proficiency testing of instruments-a keyelement for quality assurance in X-ray powder diffraction.Part 1:Matching the effort to the actual needs.Mater Sci Forum.2000,321~324:144~149. 被引量:1
  • 9[14]Pepliuski B,Mueller R,et al.Proc EPDIC-6,Budapest/Hungary:August.1998. 被引量:1
  • 10[15]Berti G.Powder Diffr.2001,16(1):1~5. 被引量:1

同被引文献28

  • 1涂彧,蒋雪峰,符荣初,刘犁.苏州市部分地区土壤总α和总β放射性水平[J].工业卫生与职业病,2004,30(6):339-341. 被引量:7
  • 2李芳,陆继根,沙连茂,蒋云平,徐萍.固体中总α、总β放射性监测方法研究[J].辐射防护,2007,27(4):228-232. 被引量:14
  • 3JJG629-1989多晶X射线衍射仪检定规程[S].1989. 被引量:1
  • 4Freiman S W, Trahey N M. Certificate: Standard Ref- erence Material 640c[S]. Gaithersburg, MD USA: National Institute of Standards and Technology, 2000. 被引量:1
  • 5Kubicek K, Braun J, Bruhns H, et al. High-precision laser-assisted absolute determination of X-ray diffraction angles[J]. Review of Scientific Instruments, 2012, 83(1) : 013102-013108. 被引量:1
  • 6Palermo R N, Short S M, Anderson C A, et al. De- termination of figures of merit for near-infrared and Ra- man spectrometry by net analyte signal analysis for a 4- component solid dosage system [J]. Journal of Pharmaceuticallnnovation, 2012, 7(2): 56-68. 被引量:1
  • 7Siaudinyte L, Bmeas D, Rybokas M, et al. Polyno- mial error approximation of a precision angle measuring system [J]. Geodesy and Cartography, 2013, 39(1) : 7-10. 被引量:1
  • 8Blanton T, Huang T, Toraya H, et al. JCPDS-- international centre for diffraction data low-angle powder diffraction study of silver behenate [C]//Advances in X- Ray Analysis. USA, 1995: 99-105. 被引量:1
  • 9Wong-Ng W, McMurdie H F, Hubbard C R, et al. JCPDS-ICDD research associateship(Cooperative pro- gram with NBS/NIST) [J]. Journal of Research of the National Institute of Standards and Technology, 2001, 106(6): 1013-1028. 被引量:1
  • 10Byun S H, Prestwich W V, Chin K, et al. Efficiency calibration and coincidence summing correction for a 4 NaI(T1)detector array[J]. Nuclear Instruments and Methods in Physics Research, 2004, 535(3): 674- 685. 被引量:1

引证文献6

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部