期刊文献+

用二维等效电路模型研究大截面圆柱变幅杆的振动 被引量:2

Vibration of column horn with large aspect ratio by 2-D equivalent circuit
下载PDF
导出
摘要 由振动方程的近似解得到了具有大尺寸比的圆柱变幅杆的二维等效电路,用于带外载或不带外载的圆柱轴对称振动分析,以及尺寸比变化引起的频率变化评价。与有限元及一维模型进行了对比。发现该模型计算频率比一维模型更准确,与有限元模态分析相一致。进而由此确定了这些频率所对应的振动模态。计算发现轴向和周向水负载对应的圆柱振动频率接近,可用于超声变幅杆的优化。 A 2-D equivalent circuit of column horn with large aspect ratio is obtained from an approximated solution of vibration equations. It is used in axisymmetric vibration analysis with or without external load, and also Comparison is made with other used in models frequency variation evaluation due to various aspect ratios. such as the finite element and the traditional 1-D models. It has been shown that this model gives a more accurate frequency calculation than the 1-D models, and agrees with the finite element mode analysis. In turn, the frequency associated vibration mode is determined. When water-loaded, in these two cases are rather close. This model axially or circumferentially, vibration frequencies is expected to have a further use in optimizing ultrasound horn.
出处 《声学技术》 CSCD 北大核心 2007年第1期149-152,共4页 Technical Acoustics
基金 国家自然科学基金(10474110) 重大基础研究前期研究专项(NO:2002CCA03400)
关键词 超声变幅杆 等效电路 振动 ultrasonic horn equivalent circuit vibration
  • 相关文献

参考文献5

  • 1林仲茂著..超声变幅杆的原理和设计[M].北京:科学出版社,1987:265.
  • 2袁易全著..超声换能器[M].南京:南京大学出版社,1992:442.
  • 3赖一楠,刘向东,罗建伟,金长善.级联式变幅杆有限元分析[J].哈尔滨理工大学学报,2001,6(1):50-52. 被引量:7
  • 4James R.Hutchinson.Axisymmetric vibration of a free finite-length rod[J].The Journal of the Acoustical Society of America,1971,51(1):233-240. 被引量:1
  • 5周光平,梁明军,王家宣.大尺寸超声振动体的研究[J].声学技术,2004,23(3):183-188. 被引量:14

二级参考文献12

  • 1林仲茂,陆建华.A1超声塑焊变幅器的有限元分析[J].声学技术,1996,15(4):153-156. 被引量:5
  • 2姜礼尚.有限元方法及理论基础[M].北京:人民教育出版社,1982.. 被引量:1
  • 3龙柏林.基于有限元方法的超声波马达建模与优化:哈尔滨工业大学硕士论文[M].,1998.9-12. 被引量:1
  • 4[2]Mori E,Itoh K,Imamura A.Analysis of a short column vibrator by apparent elasticity method and its application[A].Ultrasonic International 1997 Conference Proceedings[C].IPC Science and technology press.1977,262-266 被引量:1
  • 5任树初.压电振子的多维耦合振动(Ⅰ)-纯压电振子[J].声学学报,1983,8(3):147-157. 被引量:3
  • 6[4]Mori E,Yamakoshi K.Coupled vibration of a cylindrical shell for radiating high intensity ultrasound[J].Ultrasonics,1979,3:81-83. 被引量:1
  • 7[7]Antonio Iula,Fernando Vazquez,Massimo Pappalardo,Juan A.Gallego,Finite element three-dimensional analysis of the vibrational behaviour of the Langevin-type transducer[J].Ultrasonics,2002,40:513-517. 被引量:1
  • 8[9]Andrea Cardoni,Margaret Lucas.Enhanced vibration performance of ultrasonic block horns[J].Ultrasonics,2002,40:365-369. 被引量:1
  • 9[10]Kazunari Adachi,Sadayuki Ueha.Modal vibration control of large ultrasonic tools with the use of wave-trapped horns[J].1990: 208-214. 被引量:1
  • 10[11]Lucas M,Smith A C.Redesign of ultrasonic block horns for improved vibration performance[J].1997,7:410-414. 被引量:1

共引文献19

同被引文献21

  • 1KARUMANCHI R,DODDAMANE S N,SAMPANGI C,et al. Field-assisted extraction of cells, particles and macromolecules[J]. Trend in Biotechnology, 2002,22 (2): 72-78. 被引量:1
  • 2HARRIS N R,HILL M,BEEBY S,et al. A silicon microfluidie ultrasonic separator[J]. Sens Actuators B, 2003,95 ( 1/3) : 425-434. 被引量:1
  • 3MAN NEBERG O, SVENNEBRING J, HERTZ H M, et al. Wedge transducer design for two-dimensional ul- trasonic manipulation in a microfluidic chip[J]. Journal of Micromechanics and Microengineering, 2008,18 (9) : 1-9. 被引量:1
  • 4NEILD A,OBERTI S,RADZIWILL G,et al. Simulta- neous positioning of cells into two-dimensional Arrays using ultrasound [J]. Biotechnology and Bioengineer- ing,2007,97(5) :1335-1339. 被引量:1
  • 5LILLIEHORN T, NILSSON M, SIMU U, et al. Dy- namic arraying of microbeads for bioassays in mi- crofluidic channelsJ-J]. Sensors b- Actuators B, 2005, 106(2) 1851-858. 被引量:1
  • 6EVANDER M,JOHANSSON L, LILLIEHORN T, et al. Noninvasive acoustic cell trapping in a microfluidic perfusion system for online bioassays[J]. Anal Chem, 2007,79(7) :2984-2991. 被引量:1
  • 7HAGSATER S M,GLASDAM J T,BRUUS H,et al. Acoustic resonances in microfluidic chips: Full-image micro-PIV experiments and numerical simulations[J]. Lab on a Chip,2007,7(10):1336-1344. 被引量:1
  • 8TOWNSEND R J, HILL M, HARRIS N R,et al. In- vestigation of two-dimensional acoustic resonant modes in a particle separator[J]. Ultrasonics,2006,44(Suppl. 1) : e467-e471. 被引量:1
  • 9OBERTI S, NEILD A, DUAL J. Manipulation of micrometer sized particles within a micromachined fluidic device to form two-dimensional patterns using ultra- sound[J]. J Acoust Soc Am, 2007,121 (2) : 778-785. 被引量:1
  • 10HUA Chenhui,DING Jiexiong, WANG Yuxiang. Research on normal vibration modes and lateral standing wave in MEMS ultrasonic separator[C]//Cbangchun, China:In Proceedings of the 2009 IEEE International Conference on Mechatronics and Automation, 2009: 318-322. 被引量:1

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史