摘要
目的通过试验,找出静脉输液瓶盖消毒加药后有效消毒时限,确定再次消毒时间。方法取210瓶液体作为试验样本,分为7组,30瓶,组,按常规加药消毒,放置。分别在加药后即时及加药后的5,10,15,20,25,30min7个时间段对瓶盖进行采样,送细菌室进行细菌培养、鉴定。结果7个时间段瓶盖细菌污染情况比较χ^2=3.822,P〉0.05,菌种分布情况比较χ^2=25.32,P〉0.05,差异无统计学意义。结论静脉输液瓶盖消毒加药后在空气、物表细菌学监测结果符合标准要求的治疗室放置30min内其消毒效果仍达国家标准,在此时间段内更换该瓶液体,接瓶前无需重新消毒。
Objective To study the valid re-sterilizatlon time for capsules during the venous transfusion. Methods Divided 210 bottle of drugs for venous transfusion into 7 groups radomly, there were 30 bottles in the each group, and then sterilized according to the routine method. Sampling the capsules at the time points of dispensation immediately, 5 minutes, 10 minutes, 15 minutes, 20 minutes, 25 minutes and 30 "minutes after the dispensation, and then observed the condition of bacterial pollution. Results There was no significant difference between the different sampling stages about bacterial pollution, χ^2=3.838 ,P〉0.05. There was no significant difference in the aspect of strain distribution, χ^2=25.32, P〉0.05. Conehlsions Re-sterilizatiou should not be done for the capsules during the venous transfusion ff in the normative cure unit and within 30 minutes.
基金
来宾市2005年科技攻关项目(053101)
关键词
静脉输液
消毒
临床观察
Venous transfusion
Sterilization
Clinical observation