摘要
本文介绍了在500kV杆塔模型上进行的冲击响应试验和短尾波下绝缘子串闪络特性试验,提出了利用短尾波闪络特性估算500kV线路防雷性能的方法。
This paper presents the results of lightning surge response tests on a transmission tower model and the insulation performance of 500kV insulator strings stressed by short-tail impulses. A new method for estimating the lightning performance of transmission lines from the flashover characteristics of short-tail impulses is recommended.
出处
《电网技术》
EI
CSCD
北大核心
1990年第4期51-57,共7页
Power System Technology