摘要 应用间接复位、经皮穿钢板治疗胫骨骨折,既可为骨折端提供足够的稳定,又可最大限度地保留骨折周围软组织的血液循环及骨折端的血肿,骨折愈合快,并发症少,是近几年出现的新技术,是AO生物接骨理论的最新应用。自2002年至2004年,笔者应用这一技术治疗胫骨骨折19例,取得满意疗效。现报告如下。
出处 《中华创伤杂志》 CAS CSCD 北大核心 2006年第12期940-941,共2页 Chinese Journal of Trauma
  • 相关文献

参考文献6

  • 1Borrelli J,Pprickett W,Song E,et al.Extrosseous blood supply of the tibia and the effects of different plating techniques:a human cadaveric study.J Orthop Trauma,2002,16:619-615. 被引量:1
  • 2Borg T,Larsson S.Percutaneous.plating of distal tibial fractures:preliminary results in 21 patients.Injury,2004,35:608-614. 被引量:1
  • 3Redfen DJ,Syed SU,Davies SJ.Fractures of the distal tibia minimally invasive plate osteosynthesis.Injury,2004,35:615-620. 被引量:1
  • 4Collinge C,Sanders R,Dipasquale T.Treatment of complex tibial perarticular fractures using percutaneous techniques.Clin Orthop,2000,(375):69 -77. 被引量:1
  • 5Tornkvist H,Hearn TC,Schatzker J.The strength of plate fixation in relation to number and spacing of bone screw.J Orthop Trauma,1996,10:204-208. 被引量:1
  • 6Field RJ,Tornkvist H,Hearn TC,et al.The influence of screw omission on construct stiffness and bone surface strain in the application of bone plate to cadaveric bone.Injury,1999,30:591-598. 被引量:1

同被引文献30

  • 1Krettek C, Schandelmaier P, Miclau T, et al. Minimally invasive percu- taneous plate osteosynthesis( MIPPO ) using the DCS in proximal and di- stal femoral fractures. Injury, 1997, 28( 1 Suppl ): 20-30. 被引量:1
  • 2Krettek C, Schandelmaier P, Miclau T, et al. Minimally invasive percu- taneous plate osteosynthesis( MIPPO )using the DCS in proximal and distal femoral fractures. Injury, 1997, 28( 1 Suppl ): 31-41. 被引量:1
  • 3Wenda K, Runkel M, Degreif J, et al. Minimally invasive plate fixation in femoral shaft fractures. Injury, 1997, 28( 1 Suppl ): 13-19. 被引量:1
  • 4Krettek C , Mailer M , Mielau T. Evolution of minimally invaslve plate oeteosynthesis( MIPO )in the femur, lnjmy, 2001, 32( Snppl3 ): SC14-23. 被引量:1
  • 5Miclau T, Martin RE. The evolution of modern plate osteosynthesis. Injury, 1997,28( 1 Suppl ): 3-6. 被引量:1
  • 6Chrisovitsinos JP, Xenakis T, Papakostides KG. Bridge plating osteosyn- thesis of 20 comminuted fractures of the femur. Aeta Orthop Scand Suppl, 1997, 275 : 72-76. 被引量:1
  • 7Aksekili M A, Cetik I. The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures [J]. Acta Orthop Traumatol Turc, 2012,46(3) : 161-167. 被引量:1
  • 8Kim J W, Oh C W. Minimally invasive plate osteosynthesis for open fractures of the proximal tibia [J]. Clin Orthop Surg, 2012,4(4) :313-320. 被引量:1
  • 9Ronga M, Longo U G. Minimally invasive locked plating of distal tibia fractures is safe and effective [J]. Clin Orthop Relat Res, 2010,468(4) :975-82. 被引量:1
  • 10Ozkaya U, Parmaksizoglu A S. Minimally invasive treatment of distal tibial fractures with lucking and non-locking plates [J]. Foot Ankle Int, 2009,30 (12) : 1161-1167. 被引量:1