摘要
结合工程实例,分别介绍了高空喷淋,高空水炮,远控消防炮在该工程的运用情况,分析了这三种消防系统的优缺点。认为高空喷淋系统不宜扩大其适用的高度范围,而高空水炮系统及远控消防炮系统对于大空间场所的消防设计比喷淋系统更有优势,应大力推广应用。
This paper introduces the high - altitude spray, the high - altitude water cannon and the remote - control fire - fighting cannon respectively in a project example and the merits and defects of the three fire - fighting systems are analyzed. We come to the conclusion that the headroom height scale of the high - altitude spray system should not be extended further, and the high - altitude water cannon system and the remote - control fire - fighting cannon system have more advantages over the routine auto - spray fire - fighting system, thus their application should be greatly advocated.
出处
《福建建筑》
2006年第5期98-99,103,共3页
Fujian Architecture & Construction
关键词
高空喷淋
高空水炮
远控消防炮
大空间场所
消防
规范
High- altitude spray, High- altitude water cannon, Remote -control fire -fighting cannon, Large space locale, Code for fire - fighting