期刊文献+

自动喷水灭火系统喷头基本特征参数对比与选用分析 被引量:1

Basic Parameter Contrast and Sprinkler Selection Analysis in Fire Sprinkler System
下载PDF
导出
摘要 改善消防喷淋喷头性能及新品种的开发是为自动喷水灭火系统中的研究热点。结合喷头的流量系数、热敏指数(RTI)等各征参数及一些工程实际中的使用情况,对闭式喷头的适用场所及选用时应注意的几个方面进行了比较与说明,为设计应用项特自动喷水灭火系统时喷头的选用提供方便。 In recent years, many new varieties of automatic sprinkler have been developed in order to improve the performance of fire suppression system.But at the same time, it rised the complexity and confusion in sprinkler selection..Based on the contrast in basic parameter of sprinklers includes : flux coefficient (K),response time index (RTI),etc ;this article make a analysis and explanation on sprinkler selection in project,and give some points which should be noticed as well. The purpose is to provide the project designer with some useful information and guidance.
出处 《工程建设与设计》 2006年第2期39-41,共3页 Construction & Design for Engineering
关键词 自动喷水灭火系统 闭式喷头 特征参数 喷头选择 fire sprinkler system automatic sprinkler parameter sprinkler selection