摘要
结合电厂炉烟处理循环冷却水防垢机理,在实验室条件下,利用自主设计制造的炉烟处理循环冷却水防垢模拟试验台,进行了炉烟防垢动态模拟试验研究。试验结果表明,炉烟防垢法在低浓缩倍率及pH<8的条件下,防垢效果尤为显著。
Combining with scale prevention mechanism of using the flue gas for treating circulating cooling water in power plants, and under laboratroy conditions, a self-designed and self-made simulated test-bed is used for treating circulating cooling water to prevent scaling. The scale inhibition simulated test is carried on by using flue gas. The results show that when the concentration is low and the pH value is lower than 8, the scale prevention rate is the most remarkable.
出处
《工业水处理》
CAS
CSCD
北大核心
2006年第6期36-38,共3页
Industrial Water Treatment
基金
内蒙古自治区高等学校科学研究重大项目(NJ02020)
关键词
炉烟
循环冷却水
防垢
flue gas
circulating cooling water
scale prevention