摘要
介绍了聊城发电厂一期工程2×600MW机组、菏泽发电厂二期2×300MW机组“W”锅炉ABBUVISOR火焰检测系统的使用情况。根据实际经验,对UVISOR火检的静态、热态调试进行了说明,较好地解决了火检探头窥视的问题,对同类型机组的火检调试具有参考价值。
This article introduces the using status of ABB UVISOR flame scanners in the W-type boilersof 2×600 MW units in the first phase project of Liaocheng Power Plant, and explains the static and hot state adjnstment and testings of UVISOR flame scanners on the basis of practical experience, with the flame peeping problem of scanner probe better solved, This experience has the reference value for the adjustment and testings of flame seanners of same type units,
出处
《电力设备》
2005年第11期61-62,共2页
Electrical Equipment
关键词
火检系统
原理
结构
安装
调试
flame seanning system
principle and configuration
mounting
adjustment and testing