通过对取样、制样、分析条件等相关因素的选择,建立了钢中氢的测定方法。方法检测下限为0.15μg/g,结果准确可靠。
A method for determination for hydrogen in steel and its sampling and samples preparation process are described in this paper. The detection limit of the method is 0.15μg/g. The results are accurate and reliable.
出处
《重庆科技学院学报(自然科学版)》
CAS
2005年第3期32-33,39,共3页
Journal of Chongqing University of Science and Technology:Natural Sciences Edition
关键词
咏冲加热
热导池
氢
pulse heating
TCD
hydrogen