摘要 射线在体内的衰减和散射可影响正电子符合探测图像的质量,因此,多种衰减校正(AC)方法已用于临床[1].起搏器、人工关节、造影剂等金属异物在基于CT的AC过程中可能造成衰减过度补偿,产生阳性伪影,致临床误诊[2-4].了解金属异物产生伪影的原因及如何识别伪影对提高符合探测图像质量较为重要.本研究通过模型实验,观察金属异物对正电子符合探测图像非均匀AC的影响,现报道如下.
出处 《中华核医学杂志》 CAS CSCD 北大核心 2005年第5期312-312,共1页 Chinese Journal of Nuclear Medicine
  • 相关文献

参考文献4

  • 1Paul EK, Bruce HH, Thomas B. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners. Semin Nucl Med, 2003, 33: 166-179. 被引量:1
  • 2陆汉魁.PET显像的散射校正和衰减校正[J].中华核医学杂志,2004,24(1):58-60. 被引量:11
  • 3Goerres GW, Ziegler SI, Burger C, et al. Artifacts at PET and PET/CT caused by metallic hip prosthetic material. Radiology, 2003, 226:577-584. 被引量:1
  • 4Cohade C, Osman M, Nakamoto Y, et al. Initial experience with oral contrast in PET/CT:phantom and clinical studies. J Nucl Med, 2003,44: 412-416. 被引量:1

二级参考文献5

  • 1C. Burger,G. Goerres,S. Schoenes,A. Buck,A. Lonn,G. von Schulthess. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients[J] 2002,European Journal of Nuclear Medicine and Molecular Imaging(7):922~927 被引量:1
  • 2Jonathan M. Links. Advances in nuclear medicine instrumentation: considerations in the design and selection of an imaging system[J] 1998,European Journal of Nuclear Medicine(10):1453~1466 被引量:1
  • 3Dale L. Bailey. Transmission scanning in emission tomography[J] 1998,European Journal of Nuclear Medicine(7):774~787 被引量:1
  • 4Frank M. Bengel,Sibylle I. Ziegler,Norbert Avril,Wolfgang Weber,Christian Laubenbacher,Markus Schwaiger. Whole-body positron emission tomography in clinical oncology: Comparison between attenuation-corrected and uncorrected images[J] 1997,European Journal of Nuclear Medicine(9):1091~1098 被引量:1
  • 5Hermann Ostertag,Wolfgang K. Kübler,Josef Doll,Walter J. Lorenz. Measured attenuation correction methods[J] 1989,European Journal of Nuclear Medicine(11):722~726 被引量:1

共引文献10

同被引文献5

  • 1张彦彬,朱家瑞.钡餐造影致^(18)F-FDG符合线路显像假阳性一例[J].中华核医学杂志,2005,25(5):300-300. 被引量:2
  • 2Kinahan PE, Hasegawa BH, Beyer T,et al. X-ray-based attenuation correction for positron emission tomography/computed tumography scanners. Semi Nucl Med, 2003, 33: 166-179. 被引量:1
  • 3Goerres GW, Ziegler SI, Burger C, et al. Antifacts at PET and PET/CT caused by metallic hip prosthetic material. Radiology, 2003, 226: 577-584. 被引量:1
  • 4Cohade C,Osman M, Nakamoto Y, et al. Initial experience with oral contrast in PET/CT: phantom and clinical studies. J Nucl Med, 2003, 44: 412-416. 被引量:1
  • 5Nehmeh SA, Erdi YE, Kalaigian H, et al. Correction fot oral contrast artifacts in CT attenuation-corrected PET images obtained by combined PET/CT. J Nucl Med, 2003, 44:1940-1944. 被引量:1