在蒸汽测量中弯管流量计采用水平导压管取代冷凝罐 被引量:3

The Feasibility Analysis of Elbow Flowmeter Adopting to the Plane Guiding Press Pipe to Replace the Condensation jar in the Process of Steam Measurement
下载PDF
导出
摘要 讨论了弯管流量计在蒸汽测量中使用冷凝罐对计量精度的影响,重点进行弯管流量计采用水平导压管用于蒸汽测量的可行性分析,得出可以用水平导压管取代冷凝罐的结论。 This article aims to discuss the effect of elbow flowmeter upon the computation accuracy when a condensation jar is conducted in the process of steam measurement. It focuses on analysis of the feasibility of steam measurement which adopts the plane guiding press pipe in the facility of elbow fiowmeter. As far as the conclusion is reached, condensation jar can be replaced by the plane guiding press pipe.
出处 《河北理工学院学报》 2005年第2期98-101,共4页 Journal of Hebei Institute of Technology
关键词 弯管流量计 导压管 冷凝罐 蒸汽 elbow flowmeter plane guiding press pipe condensation jar steam
  • 相关文献

参考文献2

  • 1陆煜,程林编著..传热原理与分析[M].北京:科学出版社,1997:529.
  • 2李玉柱,苑明顺编..流体力学[M].北京:高等教育出版社,1998:350.