通过实验测定了扩散控制条件下固定床电化学反应器床层内的电势分布,实验结果同电势分布模型的计算结果吻合,从而通过实验验证了本文(I)所建立的电势分布模型的正确性。
An experimental study of the potential distribution in a packed bed electrochemical reactorunder mass-transfer controlling conditions is presented.Good agreement is obtained betweenthe theoretical predictions presented in part I and those obtained by the experimental results.It is verified that the reactor model presented in part I of this study is suitable for the process.