摘要
建立了测定固定床电化学反应器床层内电势分布的实验装置,由计算机采样测定了床层内的电势分布,并将实验结果与文献中的模型计算结果进行了比较,证明了文献所建立的反应器模型和模型方程求解方法的正确性.在不同操作模式下用实验方法考察了各因素对床层内电势分布的影响.
An experimental set up which can be used to measure the potential distribution in a packed bed electrochemical reactor by an automatic data collection system was installed. Experiments were carried out to check with the model presented in the literature[2,3] of the study. The experimental data are in good agreement with the model calculations. The mentioned model is verified to be a general one which can be used for different operating regimes. The factors effecting on the potential distribution in the packed bed is also discussed.
出处
《化工学报》
EI
CAS
CSCD
北大核心
1993年第4期383-388,共6页
CIESC Journal
基金
国家自然科学基金
博士点基金资助项目
关键词
固定床
电化学反应器
电势分布
packed bed, electrochemical reactor, potential distribution