期刊文献+

平圩电厂2号锅炉分隔屏爆管原因分析及其解决措施 被引量:1

Bursts of a Divided Platen's Tubes of Pingwei Power Plant's No.2 Boiler-Causes and Remedies
下载PDF
导出
摘要 安徽淮南平圩发电有限责任公司的2号锅炉是采用美国CE公司技术,由哈尔滨锅炉厂设计制造的我国首批60万千瓦亚临界燃煤锅炉,自2003年7月2日以来,分隔屏左数第4片屏超温爆管,通过计算和试验发现,由于连接第3、4片屏炉外管的阻力大,流量小,并与宽度方向上的热偏差及同屏热偏差,几者叠合,造成3号、4号屏超温严重。通过研究找出了产生超温爆管的原因,并提出了攻关方案,现正在施工中。 No.2 boiler of Anhui Huainan Pingwei Power Plant belongs to the first batch of 600 MW subcritical coal firing boilers designed and manufactured in this country by Harbin Boiler Works with licensed CE company's technology. Since July 2nd, 2003, the 4th divided platen from the left incurred tube overheating and bursts. Calculation and tests revealed that due to coincident overlapping of reduced flow caused by too high a flow resistance of the exterior pipe connecting the 3rd and 4th platen with heating deviation between platens along the boiler's breadth as well as within the platen, effected serious overheating of the 3rd and 4th platen. Research revealed the cause of overheating and provided means of solving the problem.
出处 《动力工程》 EI CSCD 北大核心 2005年第3期352-358,共7页 Power Engineering
关键词 动力机械工程 锅炉 分隔屏 热偏差 超温 power and mechanical engineering boiler divided platen thermal deviation overheating
  • 相关文献

同被引文献4

  • 1朱伟明,胡兴胜,方晓东,李晋,肖华.平圩发电厂2号锅炉再热器的超温原因及改进措施[J].动力工程,2005,25(1):32-39. 被引量:10
  • 2王孟浩,杨宗煊,等.屏式过热器同屏热偏差的成因和计算方法[Z].上海发电设备成套设计研究所,1984(9). 被引量:2
  • 3王孟浩,杨宗煊.电站锅炉对流过热器和高温对流再热器管束同片各管热偏差的成因和计算方法[Z].上海发电设备成套设计研究所,1984(9). 被引量:2
  • 4邵慰骏.再热器同片各管热偏差的成因和计算方法[Z].上海发电设备成套设计研究所,1984(9). 被引量:2