光阴极RF腔注入器中热发射度的测量研究(英文) 被引量:2

Invetisgation of Thermal Emittance Measurement in RF Photoinjector
原文传递
导出
摘要 论文介绍RF腔光阴极注入器中热发射度的测量方法,在注入器中有三个因素影响热发射度的测量,它们是:射频场效应、空间电荷效应和发射度测量误差。在注入器出口处,电子束发射度由:热发射度、射频场效应引起的发射度增长和空间电荷效应的发射度增长三部分组成。论文从注入器中发射度增长理论和模拟出发,给出了一个能够消除射频场效应和空间电荷效应的热发射度测量方法. A new method for the measurement of the thermal emittance in the RF photoinjector is introduced in the paper. The measurement are affected mainly by three factors which are the RF effect, the space charge effect and the error of measurement. According to the theory of emittance growth in the RF photoinjector and the simulation, a new method to eliminate the RF effect is proposed for the thermal emittance measurement in RF photoinjector. Error of measurements is not included, and the space charge effect is also ignored on the condition of the low charge operation mode.
作者 李正红
出处 《高能物理与核物理》 CSCD 北大核心 2005年第6期615-618,共4页 High Energy Physics and Nuclear Physics
基金 国家自然科学基金(10347009)资助~~
关键词 热发射 RF腔光阴极注入器 自由电子激光 多缝测量法 射频场效应 thermal emittance, RF photoinjector, FEL, multi-slit methods
  • 相关文献

参考文献2

二级参考文献2

  • 1Li Zhenghong,SPIE.3862,1999年,3862卷,240页 被引量:1
  • 2克希奈尔 W.,固体激光工程,1980年 被引量:1

共引文献4

同被引文献7

引证文献2

相关作者