摘要
调峰参数的确定关系到供暖系统的设备容量选择,以及运行过程中的经济性问题。基于末端散热设备为散热器,在热稳定条件下,通过分析散热器供回水温度及系统流量与室外温度的函数关系,得出供暖调峰时的调峰室外启动温度、调峰运行时低温热源与调峰热源各自承担的负荷比例,并进一步分析了低温热源出力比例最大时的运行流量和流量分界温度的确定,以及低温热源与调峰热源的出力负荷分布。
The relationship between design and peak shaving parameter, the capacity of heating system equipment and the economy has been presented. Based on the radiator as end heater under thermal steady condition, the working temperature for shaving heating peak load, the percentage of low temperature heat source and shaving peak heat source etc. has been analyzed. The operating temperature and flux, the heating load distribution and shaving peak heat source, under the maximum heating load have been investigated.
出处
《太阳能学报》
EI
CAS
CSCD
北大核心
2005年第1期69-72,共4页
Acta Energiae Solaris Sinica
关键词
低温热源
供暖调峰
启动温度
运行流量
负荷比例
low temperature heat source
heating peak
working temperature
operating flux
percentage of load