期刊文献+

低温热源调峰供暖的最佳工况与参数 被引量:3

THE OPTIMUM SHAVING PEAK PARAMETER AND CONDITION OF SPACE HEATING BY LOW TEMPERATURE SOURCE
下载PDF
导出
摘要 调峰参数的确定关系到供暖系统的设备容量选择,以及运行过程中的经济性问题。基于末端散热设备为散热器,在热稳定条件下,通过分析散热器供回水温度及系统流量与室外温度的函数关系,得出供暖调峰时的调峰室外启动温度、调峰运行时低温热源与调峰热源各自承担的负荷比例,并进一步分析了低温热源出力比例最大时的运行流量和流量分界温度的确定,以及低温热源与调峰热源的出力负荷分布。 The relationship between design and peak shaving parameter, the capacity of heating system equipment and the economy has been presented. Based on the radiator as end heater under thermal steady condition, the working temperature for shaving heating peak load, the percentage of low temperature heat source and shaving peak heat source etc. has been analyzed. The operating temperature and flux, the heating load distribution and shaving peak heat source, under the maximum heating load have been investigated.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2005年第1期69-72,共4页 Acta Energiae Solaris Sinica
关键词 低温热源 供暖调峰 启动温度 运行流量 负荷比例 low temperature heat source heating peak working temperature operating flux percentage of load
  • 相关文献

参考文献4

二级参考文献3

  • 1孙刚,贺平.供热工程.新1版.北京:中国建筑工业出版社,1993 被引量:1
  • 2王义贞,方修睦.热水供暖网路.北京:经济日报出版社,1994 被引量:1
  • 3吴荣华.[D].哈尔滨:哈尔滨工业大学,2001. 被引量:1

共引文献2

同被引文献13

引证文献3

二级引证文献8