本恒温恒湿气雾消毒室主要有消毒室、调温调湿箱、动力系统、控制台和气溶胶发生及采样操作箱等部分组成。消毒室用3mm厚的不锈钢板制作,容积为500L,不管是动态(1~8rpm)还是静态都具有良好的密闭性。以0.2%荧光素钠气溶胶作为消毒室的物理衰亡测定剂,2小时物理损耗为19%。观察大肠杆菌气溶胶粒子在消毒室内的动力学变化,0min胶龄的粒数中值直径(CMD)为3.6μm;120min为3.1μm;标准差介于1.73~1.60μm。消毒室外的调温调湿箱,容积为300L。该箱的温湿度调整范围分别为0~40℃和10~100%。经使用考核证明,本恒温恒湿气雾消毒室性能良好。
he aerosol equipment for disinfection consists of aerosol
storagechamber,air conditioning room,power system, control panel and opera-tion room for
aerosol generation and sampling. The aerosol storage cham-ber(500L) is air-tight at both of the
static or moving(1-8rpm) condi-tions.The physical decay of sodium fluorescein aerosol is 19%at
theaerosol age of 2 hours.The count median diameters(CMD)of Escher-chia coli aerosol are 3.6
μm and 3.1μm at the aerosol age of 0 and 2 hoursrespectively. The temperature and relative
humidity(RH) in aerosol stora-ge chamber could be controlled between 0~40℃ and RH 10~
90%.Theequipment was performed very well in a number of air disinfectant tests
出处
《解放军预防医学杂志》
CAS
北大核心
1994年第3期191-195,共5页
Journal of Preventive Medicine of Chinese People's Liberation Army
关键词
气溶胶
空气
消毒
气雾室
Aerosol,Air disinfection,Aerosol storage chamber.