摘要 本恒温恒湿气雾消毒室主要有消毒室、调温调湿箱、动力系统、控制台和气溶胶发生及采样操作箱等部分组成。消毒室用3mm厚的不锈钢板制作,容积为500L,不管是动态(1~8rpm)还是静态都具有良好的密闭性。以0.2%荧光素钠气溶胶作为消毒室的物理衰亡测定剂,2小时物理损耗为19%。观察大肠杆菌气溶胶粒子在消毒室内的动力学变化,0min胶龄的粒数中值直径(CMD)为3.6μm;120min为3.1μm;标准差介于1.73~1.60μm。消毒室外的调温调湿箱,容积为300L。该箱的温湿度调整范围分别为0~40℃和10~100%。经使用考核证明,本恒温恒湿气雾消毒室性能良好。 he aerosol equipment for disinfection consists of aerosol storagechamber,air conditioning room,power system, control panel and opera-tion room for aerosol generation and sampling. The aerosol storage cham-ber(500L) is air-tight at both of the static or moving(1-8rpm) condi-tions.The physical decay of sodium fluorescein aerosol is 19%at theaerosol age of 2 hours.The count median diameters(CMD)of Escher-chia coli aerosol are 3.6 μm and 3.1μm at the aerosol age of 0 and 2 hoursrespectively. The temperature and relative humidity(RH) in aerosol stora-ge chamber could be controlled between 0~40℃ and RH 10~ 90%.Theequipment was performed very well in a number of air disinfectant tests
出处 《解放军预防医学杂志》 CAS 北大核心 1994年第3期191-195,共5页 Journal of Preventive Medicine of Chinese People's Liberation Army
关键词 气溶胶 空气 消毒 气雾室 Aerosol,Air disinfection,Aerosol storage chamber.